ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Total reflection X-ray fluorescence analysis of uranium in the presence of competing elements

https://repo.qst.go.jp/records/81839
https://repo.qst.go.jp/records/81839
d5cd37c7-66b0-4649-a2f9-299ab7eaf1c3
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-02-16
タイトル
タイトル Total reflection X-ray fluorescence analysis of uranium in the presence of competing elements
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yukie, Izumoto

× Yukie, Izumoto

WEKO 1023622

Yukie, Izumoto

Search repository
Kodai, Takamura

× Kodai, Takamura

WEKO 1023623

Kodai, Takamura

Search repository
Tsugufumi, Matsuyama

× Tsugufumi, Matsuyama

WEKO 1023624

Tsugufumi, Matsuyama

Search repository
Nagai, Hiroki

× Nagai, Hiroki

WEKO 1023625

Nagai, Hiroki

Search repository
Sakai, Yasuhiro

× Sakai, Yasuhiro

WEKO 1023626

Sakai, Yasuhiro

Search repository
Oguri, Yoshiyuki

× Oguri, Yoshiyuki

WEKO 1023627

Oguri, Yoshiyuki

Search repository
Hiroshi, Yoshii

× Hiroshi, Yoshii

WEKO 1023628

Hiroshi, Yoshii

Search repository
Yukie, Izumoto

× Yukie, Izumoto

WEKO 1023629

en Yukie, Izumoto

Search repository
Kodai, Takamura

× Kodai, Takamura

WEKO 1023630

en Kodai, Takamura

Search repository
Tsugufumi, Matsuyama

× Tsugufumi, Matsuyama

WEKO 1023631

en Tsugufumi, Matsuyama

Search repository
Oguri, Yoshiyuki

× Oguri, Yoshiyuki

WEKO 1023632

en Oguri, Yoshiyuki

Search repository
Hiroshi, Yoshii

× Hiroshi, Yoshii

WEKO 1023633

en Hiroshi, Yoshii

Search repository
抄録
内容記述タイプ Abstract
内容記述 The analysis of uranium in environmental samples, quantified using total reflection X-ray fluorescence (TXRF) analysis, would be adversely affected by the presence of rubidium and strontium in larger amounts than uranium as coexisting elements. This is because the U Lα line at 13.61 keV is close to the Rb Kα line at 13.40 keV and the Sr Kα line at 14.17 keV. Using the U Lβ1 line (instead of the U Lα line), which does not overlap with the peaks of coexisting elements, we will be able to avoid these adverse effects. Since there is no TXRF device that can perform a quantitative analysis of uranium by using the U Lβ1 line, the following modifications were made to the existing device with the intention of rapid on-site analysis. The X-ray tube of the new device has a silver anode instead of a tungsten anode, and the sensitive area of the detector was expanded. In addition, the mechanism for adjusting the position of the sample stage was changed from manual to computerized control. These changes made it possible to screen uranium in environmental samples rapidly on site without chemical separation.
書誌情報 Spectrochimica Acta Part B: Atomic Spectroscopy

巻 173, p. 105977, 発行日 2020-11
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0584-8547
DOI
識別子タイプ DOI
関連識別子 10.1016/j.sab.2020.105977
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/abs/pii/S058485472030416X
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:06:39.892040
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3