Response of 4H-SiC Detectors to Ionizing Particles

https://repo.qst.go.jp/records/81826
https://repo.qst.go.jp/records/81826
03fbe32e-2b7e-4813-aac5-6ce92b02be44
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-02-15
タイトル
タイトル Response of 4H-SiC Detectors to Ionizing Particles
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Bernat, Robert

× Bernat, Robert

WEKO 1008107

Bernat, Robert

Search repository
Capan, Ivana

× Capan, Ivana

WEKO 1008108

Capan, Ivana

Search repository
Luka, Bakrač

× Luka, Bakrač

WEKO 1008109

Luka, Bakrač

Search repository
Brodar, Tomislav

× Brodar, Tomislav

WEKO 1008110

Brodar, Tomislav

Search repository
Takahiro, Makino

× Takahiro, Makino

WEKO 1008111

Takahiro, Makino

Search repository
Takeshi, Ohshima

× Takeshi, Ohshima

WEKO 1008112

Takeshi, Ohshima

Search repository
Željko, Pastuović

× Željko, Pastuović

WEKO 1008113

Željko, Pastuović

Search repository
Sarbutt, Adam

× Sarbutt, Adam

WEKO 1008114

Sarbutt, Adam

Search repository
Takahiro, Makino

× Takahiro, Makino

WEKO 1008115

en Takahiro, Makino

Search repository
Takeshi, Ohshima

× Takeshi, Ohshima

WEKO 1008116

en Takeshi, Ohshima

Search repository
抄録
内容記述タイプ Abstract
内容記述 We report the response of newly designed 4H-SiC Schottky barrier diode (SBD) detector prototype to alpha and gamma radiation. We studied detectors of three different active area sizes (1 × 1, 2 × 2 and 3 × 3 mm2), while all detectors had the same 4H-SiC epi-layer thickness of approximately µm, sufficient to stop alpha particles up to 6.8 MeV, which have been used in this study. The detector response to the various alpha emitters in the 3.27 MeV to 8.79 MeV energy range clearly demonstrates the excellent linear response to alpha emissions of the detectors with the increasing active area. The detector response in gamma radiation field of Co-60 and Cs-137 sources showed a linear response to air kerma and to different air kerma rates as well, up to 4.49 Gy/h. The detector response is not in saturation for the dose rates lower than 15.3 mGy/min and that its measuring range for gamma radiation with energies of 662 keV, 1.17 MeV and 1.33 MeV is from 0.5 mGy/h–917 mGy/h. No changes to electrical properties of pristine and tested 4H-SiC SBD detectors, supported by a negligible change in carbon vacancy defect density and no creation of other deep levels, demonstrates the radiation hardness of these 4H-SiC detectors.
書誌情報 Crystals

巻 11, 号 1, p. 10, 発行日 2020-12
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 2073-4352
DOI
識別子タイプ DOI
関連識別子 10.3390/cryst11010010
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/2073-4352/11/1/10
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:23:56.713016
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3