Estimation of the origins and fractions of emitted light from acrylic block during irradiation of carbon-ions

https://repo.qst.go.jp/records/81653
https://repo.qst.go.jp/records/81653
accb235a-bdcd-42ec-a812-ef9003d308c5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-11-16
タイトル
タイトル Estimation of the origins and fractions of emitted light from acrylic block during irradiation of carbon-ions
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Seiichi, Yamamoto (Nagoya Univ.)

× Seiichi, Yamamoto (Nagoya Univ.)

WEKO 1016439

Seiichi, Yamamoto (Nagoya Univ.)

Search repository
Takashi, Akagi (Hyogo Ion Beam Medical Center))

× Takashi, Akagi (Hyogo Ion Beam Medical Center))

WEKO 1016440

Takashi, Akagi (Hyogo Ion Beam Medical Center))

Search repository
Yamaguchi, Mitsutaka

× Yamaguchi, Mitsutaka

WEKO 1016441

Yamaguchi, Mitsutaka

Search repository
Kawachi, Naoki

× Kawachi, Naoki

WEKO 1016442

Kawachi, Naoki

Search repository
Mitsutaka, Yamaguchi

× Mitsutaka, Yamaguchi

WEKO 1016443

en Mitsutaka, Yamaguchi

Search repository
Naoki, Kawachi

× Naoki, Kawachi

WEKO 1016444

en Naoki, Kawachi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Although light emission from an acrylic block during irradiations of carbon-ions lower energy than the Cerenkov-light threshold was found recently, the origins and fractions of the light in the images were not yet obvious. Since light spectra may provide information to estimate the origins and fractions of the light emission, we conducted the optical imaging of acrylic block during irradiations of carbon-ions using charge coupled device (CCD) camera with optical filters. We measured the light images of acrylic block with optical filters of different wavelengths using an ultraviolet (UV) sensitive CCD camera during carbon-ion irradiations with the energy slightly higher energy to produce secondary electrons to emit Cerenkov-light (241-MeV/u). From the images, we derived the depth profiles with different wavelengths and calculated the spectra of the emitted light from acrylic block. The depth profiles showed higher intensity due to Cerenkov-light at the shallow area distributed in the images of longer wavelengths. By the calculations between depth profiles of different wavelengths, we could derive the depth profiles for possible origins of the produced light: luminescence, Cerenkov light and scintillation of acrylic block. Using the derived fractions of these components, we could estimate the depth profiles of these three components with different wavelengths.
書誌情報 Journal of Instrumentation (JINST)

巻 16, 号 1, p. P01004, 発行日 2021-01
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 1748-0221
DOI
識別子タイプ DOI
関連識別子 10.1088/1748-0221/16/01/P01004
関連サイト
識別子タイプ URI
関連識別子 https://iopscience.iop.org/article/10.1088/1748-0221/16/01/P01004
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:15:01.904268
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3