ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Landside tritium leakage over through years from Fukushima Dai‑ichi nuclear plant and relationship between countermeasures and contaminated water

https://repo.qst.go.jp/records/81600
https://repo.qst.go.jp/records/81600
0a2fd31c-e4f9-4f88-b186-b7e90bc9c90b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-01-08
タイトル
タイトル Landside tritium leakage over through years from Fukushima Dai‑ichi nuclear plant and relationship between countermeasures and contaminated water
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Shozugawa, Katsumi

× Shozugawa, Katsumi

WEKO 1044313

Shozugawa, Katsumi

Search repository
Hori, Mayumi

× Hori, Mayumi

WEKO 1044314

Hori, Mayumi

Search repository
E. Johnson, Thomas.

× E. Johnson, Thomas.

WEKO 1044315

E. Johnson, Thomas.

Search repository
Takahata, Naoto

× Takahata, Naoto

WEKO 1044316

Takahata, Naoto

Search repository
Sano, Yuji

× Sano, Yuji

WEKO 1044317

Sano, Yuji

Search repository
Kavasi, Norbert

× Kavasi, Norbert

WEKO 1044318

Kavasi, Norbert

Search repository
Kumar Sahoo, Sarata

× Kumar Sahoo, Sarata

WEKO 1044319

Kumar Sahoo, Sarata

Search repository
Matsuo, Motoyuki

× Matsuo, Motoyuki

WEKO 1044320

Matsuo, Motoyuki

Search repository
Kavasi, Norbert

× Kavasi, Norbert

WEKO 1044321

en Kavasi, Norbert

Search repository
Sahoo, Sarata

× Sahoo, Sarata

WEKO 1044322

en Sahoo, Sarata

Search repository
抄録
内容記述タイプ Abstract
内容記述 There has been tritium groundwater leakage to the land side of Fukushima Dai-ichi nuclear power plants since 2013. Groundwater was continuously collected from the end of 2013 to 2019, with an average tritium concentration of approximately 20 Bq/L. Based on tritium data published by Tokyo Electric Power Company Holdings (TEPCO) (17,000 points), the postulated source of the leakage was (1) leaks from a contaminated water tank that occurred from 2013 to 2014, or (2) a leak of tritium that had spread widely over an impermeable layer under the site. Based on our results, sea side and land side tritium leakage monitoring systems should be strengthened.
書誌情報 Scientific Reports

巻 10, p. 19925, 発行日 2020-01
出版者
出版者 Nature Publishing Group
ISSN
収録物識別子タイプ ISSN
収録物識別子 2045-2322
DOI
識別子タイプ DOI
関連識別子 10.1038/s41598-020-76964-9
関連サイト
識別子タイプ URI
関連識別子 https://www.nature.com/articles/s41598-020-76964-9
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:52:46.481943
Show All versions