ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Preliminary Clinical Analysis with Dose-Averaged LET Calculation for Head and Neck Cancer Patients Treated by Using Carbon-Ion Radiotherapy

https://repo.qst.go.jp/records/81598
https://repo.qst.go.jp/records/81598
04d52f65-c769-4841-83c8-d19a72618a7b
Item type 会議発表用資料 / Presentation(1)
公開日 2021-01-08
タイトル
タイトル Preliminary Clinical Analysis with Dose-Averaged LET Calculation for Head and Neck Cancer Patients Treated by Using Carbon-Ion Radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sung-Hyun, Lee

× Sung-Hyun, Lee

WEKO 924043

Sung-Hyun, Lee

Search repository
Yamamoto, Atsushi

× Yamamoto, Atsushi

WEKO 924044

Yamamoto, Atsushi

Search repository
Yamaoka, Keisi

× Yamaoka, Keisi

WEKO 924045

Yamaoka, Keisi

Search repository
Hotta, Eika

× Hotta, Eika

WEKO 924046

Hotta, Eika

Search repository
Yamamoto, Miyabi

× Yamamoto, Miyabi

WEKO 924047

Yamamoto, Miyabi

Search repository
Suzuki, Yui

× Suzuki, Yui

WEKO 924048

Suzuki, Yui

Search repository
Inomata, Asami

× Inomata, Asami

WEKO 924049

Inomata, Asami

Search repository
Suga, Makito

× Suga, Makito

WEKO 924050

Suga, Makito

Search repository
Koto, Masashi

× Koto, Masashi

WEKO 924051

Koto, Masashi

Search repository
Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 924052

Kohno, Ryosuke

Search repository
Sung-Hyun, Lee

× Sung-Hyun, Lee

WEKO 924053

en Sung-Hyun, Lee

Search repository
Atsushi, Yamamoto

× Atsushi, Yamamoto

WEKO 924054

en Atsushi, Yamamoto

Search repository
Keisi, Yamaoka

× Keisi, Yamaoka

WEKO 924055

en Keisi, Yamaoka

Search repository
Eika, Hotta

× Eika, Hotta

WEKO 924056

en Eika, Hotta

Search repository
Miyabi, Yamamoto

× Miyabi, Yamamoto

WEKO 924057

en Miyabi, Yamamoto

Search repository
Yui, Suzuki

× Yui, Suzuki

WEKO 924058

en Yui, Suzuki

Search repository
Asami, Inomata

× Asami, Inomata

WEKO 924059

en Asami, Inomata

Search repository
Makito, Suga

× Makito, Suga

WEKO 924060

en Makito, Suga

Search repository
Masashi, Koto

× Masashi, Koto

WEKO 924061

en Masashi, Koto

Search repository
Ryosuke, Kohno

× Ryosuke, Kohno

WEKO 924062

en Ryosuke, Kohno

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: For head and neck cancer patients treated with carbon-ion radiotherapy (CIRT), normal tissues such as brain and optic nerve are close to the irradiation field such that those may receive radiation damage. In order to estimate their clinical results, a dose-averaged LET (LETd) calculation tool was developed. We focused on the usefulness of LETd as a clinical analytical parameter.
Methods: In-house Heavy Ion Plan (HIPLAN) treatment planning system was used in the CIRT with a wobbler-scattering method. We developed the LETd and its standard deviation (LETdSD) calculation tool, and implemented in the HIPLAN. 33 head and neck patients treated with CIRT, who had follow-up more than 3 years and did not receive additional radiotherapy, were selected in order to evaluate local control and optic neuropathy. LETd and LETdSD for these 33 patients were calculated using the analysis tool.
Results: By implementing the clinical analysis tool in HIPLAN, it was possible to efficiently calculate and analyze the LETd and LETdSD for each patient. Of the 33 patients, 13 had local recurrences and 8 had optic neuropathies. Among 33 with and without recurrence cases, the mean LETd values in the PTV were 58.7±5.4 for with recurrence and 61.7±6.9 keV/m for without recurrence, respectively. On the other hand, the mean LETd values were 45.6±12.8 for with optic neuropathy and 29.0±19.0 keV/m for without optic neuropathy (p-value=0.046).
Conclusion: We developed the LETd and LETdSD calculation tool and analyzed 33 patients of head and neck cancer for local control and optic neuropathy. Although the mean LETd in the PTV were similar values between cases with and without recurrence, we could observe the usefulness of the LETd analysis for optic neuropathy cases. We will continue to analyze more patients in the future.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 AAPM2020
発表年月日
日付 2020-07-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:49:43.585004
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3