ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

RBE calculation using radiobiological computation software ‘Survival’ for human salivary gland cell

https://repo.qst.go.jp/records/81595
https://repo.qst.go.jp/records/81595
a995f4b4-58bf-4235-9ab0-806bd4d8d14e
Item type 会議発表用資料 / Presentation(1)
公開日 2021-01-08
タイトル
タイトル RBE calculation using radiobiological computation software ‘Survival’ for human salivary gland cell
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 菅, 満喜人

× 菅, 満喜人

WEKO 917654

菅, 満喜人

Search repository
本間, 大晴

× 本間, 大晴

WEKO 917655

本間, 大晴

Search repository
Sung Hyun, Lee

× Sung Hyun, Lee

WEKO 917656

Sung Hyun, Lee

Search repository
鈴木, 雅雄

× 鈴木, 雅雄

WEKO 917657

鈴木, 雅雄

Search repository
山尾, 天翔

× 山尾, 天翔

WEKO 917658

山尾, 天翔

Search repository
井出, 紳介

× 井出, 紳介

WEKO 917659

井出, 紳介

Search repository
加藤, 弘之

× 加藤, 弘之

WEKO 917660

加藤, 弘之

Search repository
橋本, 光康

× 橋本, 光康

WEKO 917661

橋本, 光康

Search repository
谷本, 克之

× 谷本, 克之

WEKO 917662

谷本, 克之

Search repository
河野, 良介

× 河野, 良介

WEKO 917663

河野, 良介

Search repository
Suga, Makito

× Suga, Makito

WEKO 917664

en Suga, Makito

Search repository
Sung-Hyun, Lee

× Sung-Hyun, Lee

WEKO 917665

en Sung-Hyun, Lee

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 917666

en Suzuki, Masao

Search repository
Kato, Hiroyuki

× Kato, Hiroyuki

WEKO 917667

en Kato, Hiroyuki

Search repository
Tanimoto, Katsuyuki

× Tanimoto, Katsuyuki

WEKO 917668

en Tanimoto, Katsuyuki

Search repository
Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 917669

en Kohno, Ryosuke

Search repository
抄録
内容記述タイプ Abstract
内容記述 [Purpose] The clinical dose in heavy ion radiotherapy is defined by calculating the biological dose based on RBE for human salivary gland (HSG) cells, and normalizing it to the clinical RBE value obtained by neutron radiotherapy. However, since irradiated various tumors and normal tissues are not HSG cells, the predicted biological dose for irradiated field may have large uncertainty. In this study, we introduced radiobiological computation software ‘Survival’ to estimate the RBE for various cells, and tried to calculate the RBE using ‘Survival’ for irradiation of HSG cells with 12C, 20Ne and 3He, ions.
[Methods] The biological dose analysis software used was ‘Survival'. PIDE ver.3.1 was used as literature data on past cell irradiation. RBE (RBESurvival) was calculated by analyzing cell survival rate with the ‘Survival’ using PEID irradiation conditions. By comparing this with RBE(RBEPEID) calculated from PEID, the accuracy of RBE calculation using the ‘Survival’ was evaluated. Microdosimetric Kinetic Model (MKM) was used for the biological effect model, and the values of each parameter required were those of previous studies. The target cells were HSG, and the irradiated particles were 12C, 20Ne, and 3He. The linear energy transfer (dose averaged LET: LETD) described in PIDE was used.
[Results] RBESurvival was generally consistent with RBEPEID. This suggests that RBE can be roughly estimated. The area where RBESurvival cannot reproduce RBEPEID was different for each particle. Also, the relationship with LET is not shown.
[Conclusion] The ‘Survival’ roughly could estimate the RBE for irradiation of HSG cells with 12C, 20Ne and 3He, ions. In the future, we will evaluate the RBE calculation accuracy of the ‘Survival’ for various cells.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第119回日本医学物理学会学術大会
発表年月日
日付 2020-05-15
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:51:47.553644
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3