ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Verification of accuracy of contact-probe distance meter for lithium target of fusion neutron source

https://repo.qst.go.jp/records/81471
https://repo.qst.go.jp/records/81471
fbcdf652-2ba1-4e2a-bf09-a4723ff6dc97
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-12-28
タイトル
タイトル Verification of accuracy of contact-probe distance meter for lithium target of fusion neutron source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Okita, Takafumi

× Okita, Takafumi

WEKO 1007150

Okita, Takafumi

Search repository
Entani, Shota

× Entani, Shota

WEKO 1007151

Entani, Shota

Search repository
Watanabe, Kotaro

× Watanabe, Kotaro

WEKO 1007152

Watanabe, Kotaro

Search repository
Higashi, Masahiro

× Higashi, Masahiro

WEKO 1007153

Higashi, Masahiro

Search repository
Hoashi, Eiji

× Hoashi, Eiji

WEKO 1007154

Hoashi, Eiji

Search repository
Kondo, Hiroo

× Kondo, Hiroo

WEKO 1007155

Kondo, Hiroo

Search repository
Park, ChangHo

× Park, ChangHo

WEKO 1007156

Park, ChangHo

Search repository
Nakamura, Makoto

× Nakamura, Makoto

WEKO 1007157

Nakamura, Makoto

Search repository
Ochiai, Kentaro

× Ochiai, Kentaro

WEKO 1007158

Ochiai, Kentaro

Search repository
Kasugai, Atsushi

× Kasugai, Atsushi

WEKO 1007159

Kasugai, Atsushi

Search repository
Hiroo, Kondo

× Hiroo, Kondo

WEKO 1007160

en Hiroo, Kondo

Search repository
Makoto, Nakamura

× Makoto, Nakamura

WEKO 1007161

en Makoto, Nakamura

Search repository
Kentaro, Ochiai

× Kentaro, Ochiai

WEKO 1007162

en Kentaro, Ochiai

Search repository
Atsushi, Kasugai

× Atsushi, Kasugai

WEKO 1007163

en Atsushi, Kasugai

Search repository
抄録
内容記述タイプ Abstract
内容記述 An accelerator based intense neutron sources such as the IFMIF, A-FNS and DONES produce neutron flux by a stripping reaction between lithium (Li) and deuteron for testing various materials for fusion reactor. In these fusion neutron sources, a liquid Li free-surface jet is applied as the liquid Li target. For the development of the Li target system, the variation in the thickness of the Li jet was measured using the Li loop of Osaka University. At the Osaka Univ., a lot of knowledge about the surface fluctuation of the Li jet had been obtained by using the electro-contact type distance meter (referred to as the probe apparatus herein). Besides, for the stable and safety operation of the facility, the probe apparatus is planned to be used as a safety interlock system for beam irradiation in actual intense neutron source because of its simple structure. Therefore, it is desirable to verify its accuracy. Especially, it is expected that false detection and undetected waves, which is particular to the contact-type apparatus, could cause errors. Then in this study, the measurement using non-contact type distance meter using optical comb (referred to as the laser probe herein) was conducted, and then the error of the results of the probe apparatus is evaluated by comparing results.
書誌情報 Fusion Engineering and Design

巻 159, p. 111799, 発行日 2020-10
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2020.111799
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0920379620303471
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:24:57.253573
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3