WEKO3
アイテム
Evaluation of a Hamamatsu TOF-PET detector module with 3.2-mm pitch LFS scintillators and a 256-channel SiPM array
https://repo.qst.go.jp/records/81432
https://repo.qst.go.jp/records/8143251da1a74-ad52-43b8-bfc2-6449e24f2fd1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-12-24 | |||||
タイトル | ||||||
タイトル | Evaluation of a Hamamatsu TOF-PET detector module with 3.2-mm pitch LFS scintillators and a 256-channel SiPM array | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Akamatsu, Go
× Akamatsu, Go× Takyu, Sodai× Yoshida, Eiji× Iwao, Yuma× Tashima, Hideaki× Nishikido, Fumihiko× Yamaya, Taiga× Go, Akamatsu× Sodai, Takyu× Eiji, Yoshida× Yuma, Iwao× Hideaki, Tashima× Fumihiko, Nishikido× Taiga, Yamaya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Using time-of-flight (TOF) information in image reconstruction improves image signal-to-noise ratio and quantitative accuracy in positron emission tomography (PET). A new TOF-PET detector module with a 3.2 mm pitch lutetium fine silicate (LFS) scintillator array one-to-one coupled to a 16×16 (256-ch) silicon photomultiplier (SiPM) array was made commercially available (C13500 series, Hamamatsu Photonics K.K.). In this study, as a candidate detector module for the next generation brain-dedicated PET, we changed the scintillator length of 20 mm to 10 mm according to our helmet-type PET geometry and investigated the basic performance of the PET detector module, including its energy resolution, sensitivity, coincidence response function (CRF) and coincidence timing resolution (CTR). All performance values were compared with those of the 4.2 mm pitch 144-ch detector module which was selected for our current helmet-type PET prototype. The energy resolution was 12% at 511 keV. The sensitivity was about 10% lower compared with those of the 4.2 mm pitch module. The average full width at half maximum (FWHM) of the CRFs was 1.9 mm. The CTRs had values of 235–241 ps with various energy windows after applying timing calibration. The CTR was not significantly changed (<10 ps) at the single count rate of 412 kcps or lower. | |||||
書誌情報 |
IEEE Transactions on Radiation and Plasma Medical Sciences 巻 5, 号 5, p. 645-650, 発行日 2021-09 |
|||||
出版者 | ||||||
出版者 | IEEE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2469-7311 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TRPMS.2020.3035876 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://ieeexplore.ieee.org/document/9248033 |