ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Evaluation of Organ Doses for Pediatric Computed Tomography Using a Newly Designed Radiophotoluminescence Glass Dosimeter and Comparison with a Monte Carlo Simulation-based Dose Calculator

https://repo.qst.go.jp/records/81243
https://repo.qst.go.jp/records/81243
49619858-e509-40f0-ad2f-e95a22d68e8d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-12-07
タイトル
タイトル Evaluation of Organ Doses for Pediatric Computed Tomography Using a Newly Designed Radiophotoluminescence Glass Dosimeter and Comparison with a Monte Carlo Simulation-based Dose Calculator
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Chang, Weishan

× Chang, Weishan

WEKO 1006187

Chang, Weishan

Search repository
Koba, Yusuke

× Koba, Yusuke

WEKO 1006188

Koba, Yusuke

Search repository
Chang, Weishan

× Chang, Weishan

WEKO 1006189

en Chang, Weishan

Search repository
Yusuke, Koba

× Yusuke, Koba

WEKO 1006190

en Yusuke, Koba

Search repository
抄録
内容記述タイプ Abstract
内容記述 Management of patient dose is an effective way to help optimize computed tomography (CT) scanning conditions and CT dose. Organ dose is one of the preferred quantities for radiation protection because of its correlation with radiation risk. To date, the WAZA-ARI dose calculator is the only freely available CT dose calculator also applicable for pediatric patients. However, no reports of its evaluation have appeared since the latest version of WAZA-ARI was released. In this study, to evaluate the latest version of WAZA-ARI, we measured the organ dose in a 5-y-old anthropomorphic phantom by a newly developed radiophotoluminescence glass dosimeter (RGD) dosimetry system and compared these results with the calculation results from WAZA-ARI. The newly designed RGDs have less angular dependence because of the additional filter. RGDs were individually calibrated with the ISOVOLT TITAN-320 x-ray generator. All the experimental measurements for this study were performed using a CT scanner. To consider the difference of CT output between the nominal and actual machine, the measured CTDIair was used to correct the calculation results obtained from WAZA-ARI. After the corrections using the measured CTDIair, the calculation results from WAZA-ARI were relatively lower than the measured results with a range of 8-20%, which corresponds to the dose difference caused by the difference in effective diameter. In conclusion, the calculation accuracy of WAZA-ARI is guaranteed when the normalization factor specific to each CT scanner (CTDIair) and the shape of the phantom are taken into consideration.
書誌情報 Health Physics

巻 120, 号 3, p. 288-295, 発行日 2021-03
出版者
出版者 Health Physics Society
ISSN
収録物識別子タイプ ISSN
収録物識別子 0017-9078
PubMed番号
識別子タイプ PMID
関連識別子 33044423
DOI
識別子タイプ DOI
関連識別子 10.1097/HP.0000000000001315
関連サイト
識別子タイプ URI
関連識別子 https://journals.lww.com/health-physics/Fulltext/2021/03000/Evaluation_of_Organ_Doses_for_Pediatric_Computed.5.aspx
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:26:03.836420
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3