WEKO3
アイテム
Intake ratio of 131I to 137Cs derived from thyroid and whole-body doses to residents of Iwaki city in Japan's Fukushima Prefecture
https://repo.qst.go.jp/records/81136
https://repo.qst.go.jp/records/811365571df29-5e11-418e-b224-00870949edfa
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-11-27 | |||||
タイトル | ||||||
タイトル | Intake ratio of 131I to 137Cs derived from thyroid and whole-body doses to residents of Iwaki city in Japan's Fukushima Prefecture | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Eunjoo, Kim
× Eunjoo, Kim× Yajima, Kazuaki× Igarashi, Yu× Tani, Kotaro× Hashimoto, Shozo× Nakano, Takashi× Akashi, Makoto× Kurihara, Osamu× Eunjoo, Kim× Kazuaki, Yajima× Yu, Igarashi× Kotaro, Tani× Shozo, Hashimoto× Takashi, Nakano× Makoto, Akashi× Osamu, Kurihara |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | It is very important to determine the precise internal thyroid doses of Fukushima residents involved in the 2011 Fukushima nuclear disaster, particularly for small children. This has been challenging due to the lack of direct human measurements to identify 131I, the biggest contributor to the thyroid doses. We previously used a dataset of late whole-body counter (WBC) measurements targeting 134Cs and 137Cs for the thyroid dose estimation in comparison with the intake ratios of 131I to 137Cs (or 134Cs) derived from thyroid and whole-body doses individually obtained from different subject groups, assuming simultaneous acute intake via inhalation. Herein, we applied the same method to the doses of residents in Iwaki city (located south of the Fukushima Daiichi Nuclear Power Plant) with a relatively high activity ratio (131I/137Cs) for the ground deposition density. Our analyses revealed that the intake ratio (131I/137Cs) for the Iwaki residents was 4.2–4.3, which is relatively consistent with the values obtained in other studies (average 3.0–5.0). No regional difference in the intake ratios from other areas was observed, but further studies are required to determine the accurate intake ratio in the early phase of the accident, in particular focusing on the reasonable interpretation of results of the late WBC measurements to evaluate the actual Cs intake. | |||||
書誌情報 |
Health Physics 巻 120, 号 4, p. 387-399, 発行日 2020-11 |
|||||
出版者 | ||||||
出版者 | Wolters Kluwer | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0017-9078 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 33229943 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1097/HP.0000000000001345 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://journals.lww.com/health-physics/Fulltext/2021/04000/Intake_Ratio_of_131I_to_137CS_Derived_from_Thyroid.3.aspx |