WEKO3
アイテム
Development of a hybrid image reconstruction algorithm combining PET and Compton events for whole gamma imaging
https://repo.qst.go.jp/records/81072
https://repo.qst.go.jp/records/810726735e929-4a4d-4a00-bc67-3be8298951ce
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-10-20 | |||||
タイトル | ||||||
タイトル | Development of a hybrid image reconstruction algorithm combining PET and Compton events for whole gamma imaging | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tashima, Hideaki
× Tashima, Hideaki× Yoshida, Eiji× Wakizaka, Hidekatsu× Takahashi, Miwako× Nagatsu, Kotaro× Tsuji, Atsushi× Kamada, Kei× Parodi, Katia× Yamaya, Taiga× Tashima, Hideaki× Yoshida, Eiji× Wakizaka, Hidekatsu× Takahashi, Miwako× Nagatsu, Kotaro× Tsuji, Atsushi× Parodi, Katia× Yamaya, Taiga |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The goal of whole gamma imaging (WGI) is to utilize all detectable gamma rays for imaging. By inserting a scatterer ring into a PET ring, the WGI detects not only 511 keV annihilation photons of positron emitters but also single gamma rays with various energies as Compton events. The Compton events include one photon of a pair of the annihilation photons in that the other photon is not detected, as well as a single gamma ray photon emitted from a non-pure positron emitter. To realize the WGI concept, it is necessary to develop an image reconstruction method combining the two different types of events. In this study, therefore, we developed a hybrid image reconstruction algorithm which utilized PET and Compton events efficiently in each iteration based on the list-mode ordered subset expectation maximization framework. For each sub-iteration of the proposed algorithm, a weighted sum of update images individually calculated for PET and Compton events was used as an update image. To demonstrate the effectiveness, we used our WGI prototype to measure a contrast phantom filled with a 89Zr solution of 9.4 MBq having a hot to background ratio of 4:1. We extracted 511 keV PET events and 909 keV Compton events by setting different energy windows in software-based coincidence detection. Reconstructed images obtained using both PET and Compton events were compared with those using PET events only and those using Compton events only. The contrast recovery against background variability for each iteration was used as a figure of merit. The results showed the image reconstructed using both PET and Compton events had better image contrast compared with other images. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | IEEE NSS&MIC 2020 | |||||
発表年月日 | ||||||
日付 | 2020-11-06 | |||||
日付タイプ | Issued |