WEKO3
アイテム
Radiosynthesis and quality control testing of the tau imaging positron emission tomography tracer [18F]PM‐PBB3 for clinical applications
https://repo.qst.go.jp/records/81043
https://repo.qst.go.jp/records/81043f28b7c3f-058a-4c2d-9e5e-80d61129f9b8
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-11-12 | |||||
タイトル | ||||||
タイトル | Radiosynthesis and quality control testing of the tau imaging positron emission tomography tracer [18F]PM‐PBB3 for clinical applications | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kawamura, Kazunori
× Kawamura, Kazunori× Hashimoto, Hiroki× Furutsuka, Kenji× Ohkubo, Takayuki× Fujishiro, Tomoya× Togashi, Takahiro× Arashi, Daisuke× Sakai, Toshiyuki× Muto, Masatoshi× Ogawa, Masanao× Kurihara, Yusuke× Nengaki, Nobuki× Takei, Makoto× Nemoto, Kazuyoshi× Higuchi, Makoto× Ming-Rong, Zhang× Kazunori, Kawamura× Hiroki, Hashimoto× Kenji, Furutsuka× Ohkubo, Takayuki× Fujishiro, Tomoya× Togashi, Takahiro× Daisuke, Arashi× Sakai, Toshiyuki× Masatoshi, Muto× Masanao, Ogawa× Kurihara, Yusuke× Nobuki, Nengaki× Makoto, Takei× Kazuyoshi, Nemoto× Makoto, Higuchi× Zhang, Ming-Rong |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recently, we produced 11C‐labeled 2‐((1E,3E)‐4‐(6‐(methylamino)pyridin‐3‐yl)buta‐1,3‐dienyl)benzo[d]thiazol‐6‐ol ([11C]PBB3) as a clinically useful positron emission tomography (PET) tracer for in vivo imaging of tau pathologies in the human brain. To overcome the limitations (i.e., rapid in vivo metabolism and short half‐life) of [11C]PBB3, we further synthesized 18F‐labeled 1‐fluoro‐3‐((2‐((1E,3E)‐4‐(6‐(methylamino)pyridine‐3‐yl)buta‐1,3‐dien‐1‐yl)benzo[d]thiazol‐6‐yl)oxy)propan‐2‐ol ([18F]PM‐PBB3). [18F]PM‐PBB3 is also a useful tau PET tracer for imaging tau pathologies. In this study, we developed a routine radiosynthesis and quality control testing of [18F]PM‐PBB3 for clinical applications. [18F]PM‐PBB3 was synthesized by direct 18F‐fluorination of the tosylated derivative, followed by removal of the protecting group. [18F]PM‐PBB3 was obtained with sufficient radioactivity (25 ± 6.0% of the nondecay‐corrected radiochemical yield at the end of synthesis, EOS), radiochemical purity (98 ± 0.6%), and molar activity (350 ± 94 GBq/μmol at EOS; n = 53). Moreover, [18F]PM‐PBB3 consistently retained >95% of radiochemical purity for 60 min without undergoing photoisomerization using a new UV‐cutoff light (yellow light) fixed in the hot cell to monitor the synthesis. All the results of the quality control testing for the [18F]PM‐PBB3 injection complied with our in‐house quality control and quality assurance specifications. We have accomplished >200 production runs of [18F]PM‐PBB3 in our facility for various research purposes. | |||||
書誌情報 |
Journal of Labelled Compounds and Radiopharmaceuticals 巻 64, 号 3, p. 109-119, 発行日 2020-11 |
|||||
出版者 | ||||||
出版者 | WILEY | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0362-4803 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 33067819 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/jlcr.3890 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/full/10.1002/jlcr.3890 |