WEKO3
アイテム
Significant changes in yields of 7-hydroxy-coumarin-3-carboxylic acid produced under FLASH radiotherapy conditions
https://repo.qst.go.jp/records/81014
https://repo.qst.go.jp/records/810141d918c1f-870d-44f4-8417-38b0b8fc2dc9
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-11-17 | |||||
タイトル | ||||||
タイトル | Significant changes in yields of 7-hydroxy-coumarin-3-carboxylic acid produced under FLASH radiotherapy conditions | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kusumoto, Tamon
× Kusumoto, Tamon× Kitamura, Hisashi× Hojo, Satoru× Konishi, Teruaki× Kodaira, Satoshi× Tamon, Kusumoto× Hisashi, Kitamura× Satoru, Hojo× Teruaki, Konishi× Satoshi, Kodaira |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | FLASH radiotherapy appears to kill off tumor cells while sparing healthy tissues, by irradiation at ultra high dose rate (>40 Gy s−1). The present study aims to clarify the mechanism of the sparing effect by proton irradiation under the FLASH conditions from a viewpoint of radiation chemistry. To do so, we evaluate radiation chemical yields (G values) of 7-hydroxy-coumarin-3-carboxylic acid (7OH–C3CA), which is produced by water radiolysis using coumarin-3-carboxylic acid (C3CA) solution as a radical scavenger of hydroxyl radicals. We shoot 27.5 MeV protons in the dose rate ranging from 0.05 to 160 Gy s−1. The recombination process of hydroxyl radicals produced is followed by varying the concentration of C3CA from 0.2 to 20 mM, which corresponds to the scavenging time scale from 7.1 to 714 ns. The G value of 7OH–C3CA produced decreases with increasing dose rate on the same scavenging time scale. Additionally, the trend of the relative G value normalized at a scavenging time scale of 100 ns, where radical–radical reaction subsides, is consistent in the examined dose rate range. This finding implies that G values of 7OH–C3CA produced reduce with increasing dose rate due to the oxygen depletion. We experimentally present that the sparing effect for healthy tissues would be seen even with a proton beam under the FLASH conditions due to the depletion of oxygen. | |||||
書誌情報 |
RSC Advances 巻 10, 号 63, p. 38709-38714, 発行日 2020-10 |
|||||
出版者 | ||||||
出版者 | The Royal Society of Chemistry | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2046-2069 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1039/D0RA07999E | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1039/D0RA07999E |