WEKO3
アイテム
Correlation analysis of organ doses determined by Monte Carlo simulation with dose metrics for patients undergoing chest-abdomen-pelvis CT examinations
https://repo.qst.go.jp/records/80897
https://repo.qst.go.jp/records/808972532798a-6f42-4739-bbeb-973861dbced0
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-08-07 | |||||
タイトル | ||||||
タイトル | Correlation analysis of organ doses determined by Monte Carlo simulation with dose metrics for patients undergoing chest-abdomen-pelvis CT examinations | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Fujii, Keisuke
× Fujii, Keisuke× Nomura, Keiichi× Muramatsu, Yoshihisa× Goto, Takahiro× Obara, Satoshi× Ota, Hiroyuki× Tsukagoshi, Shinsuke× Keisuke, Fujii× Nomura, Keiichi× Satoshi, Obara |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This study aimed to determine organ doses based on Monte Carlo (MC) simulations for individual patients undergoing routine adult chest abdomen-pelvis computed tomography (CT) examinations and to evaluate the correlations of organ doses with patient size and dose metrics. MC simulations were performed by reading detailed descriptions of the CT scanner, scanning parameters, and CT images of phantoms and patients into the simulation software. The simulation models were validated by comparing the simulated doses with the doses measured by in-phantom dosimetry using radiophotoluminescent glass dosimeters and an adult anthropomorphic phantom, and organ doses for 80 patients were determined from the simulation results. To obtain patient size and dose metrics, body mass index and volume computed tomography dose index (CTDIvol) data were collected. Water equivalent diameter (WED) was calculated from the CT images of each patient. Size-specific dose estimates (SSDE) were calculated using CTDIvol and average WED over the scan range, and organ specific SSDE were calculated using the average CTDIvol and WED over each organ position. The correlations of organ doses with dose metrics were evaluated using coefficients of determination. Organ doses increased with patient size, and the doses for obese were approximately two to three times higher than those for underweight patients. Organ doses exhibited stronger linear relationships with organ specific SSDE (R2 ≥ 0.82) than other dose metrics. The linear regression fits between organ doses determined by MC simulation and organ-specific SSDE are valuable for simplified and accurate organ dose estimation for individual patients undergoing CT examinations. |
|||||
書誌情報 |
Physica Medica 巻 77, p. 1-9, 発行日 2020-08 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1120-1797 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 32755745 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ejmp.2020.07.016 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.ejmp.2020.07.016 |