ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Discretized DOI Encoding of a Trapezoid Shape PET Detector Made Using 3D Sub-Surface Laser Engraving

https://repo.qst.go.jp/records/80860
https://repo.qst.go.jp/records/80860
1d9272cf-5032-44e6-9ceb-06b15d9f8b4c
Item type 会議発表用資料 / Presentation(1)
公開日 2020-11-02
タイトル
タイトル Discretized DOI Encoding of a Trapezoid Shape PET Detector Made Using 3D Sub-Surface Laser Engraving
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kang, Hangyu

× Kang, Hangyu

WEKO 898067

Kang, Hangyu

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 898068

en Kang, Hangyu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Previously for small animal positron emission tomography (PET), we developed the trapezoid geometry depth-of-interaction (DOI) detector using a sub-surface laser engraving (SSLE) technique. However, the required DOI calibration should be done with collimated beams which takes a long time. This problem can be solved by segmenting the detector crystal in the DOI direction using SSLE. In this study, we present the preliminary results obtained for a DOI detector with a laser processed trapezoid shape LYSO crystal for a small animal DOI PET scanner. The proposed DOI detector consisted of three trapezoid shape LYSO crystal plates. Each 20 mm long LYSO plate (top = 15.3 mm, bottom = 25.6 mm, thickness = 0.9 mm) was segmented into a 15 × 10 array by using SSLE to yield a top crystal pitch of 1.02 mm, a bottom crystal pitch of 1.71 mm, and DOI bin of 2.0 mm (10 segments). Unlike our previous work, the crystal was segmented in the DOI direction to provide discretized DOI information. The LYSO plates were optically isolated by using an enhanced specular reflector (ESR). A 7×6 array of SiPMs (S13360-2050VE, Hamamatsu Photonics, Japan) with a pixel pitch of 2.4 mm and an 8×4 array of SiPMs (S13361-3050NE-04, Hamamatsu Photonics) with a pixel pitch of 3.2 mm were coupled to the top and bottom surfaces of the trapezoid LYSO array, respectively. The SiPM output signals were multiplexed by using a resistive network, and then digitized using the CAMAC DAQ. We could identify all the 15×3 crystals in the 2D flood map of the back SiPMs. Nine of ten DOI segments could be identified and each had a 2 mm DOI bin. The measured energy resolution was 11.4±1.2%. In the future, we plan to increase the number of crystals in the axial direction to use the full sensitive area of the SiPM.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2020 Virtual IEEE Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2020-11-05
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:58:30.068561
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3