ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

First Prototyping of a Total-Body Small Animal PET with a 4-Layer DOI Detector

https://repo.qst.go.jp/records/80859
https://repo.qst.go.jp/records/80859
1828af40-b365-429a-a764-91bf963a8516
Item type 会議発表用資料 / Presentation(1)
公開日 2020-11-02
タイトル
タイトル First Prototyping of a Total-Body Small Animal PET with a 4-Layer DOI Detector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kang, Hangyu

× Kang, Hangyu

WEKO 898065

Kang, Hangyu

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 898066

en Kang, Hangyu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recently, a total-body positron emission tomography (PET) scanner, which was developed by UC Davis, enabled the total-body dynamic molecular imaging with a subsecond temporal resolution in a human study. However, when it comes to small animal PET, the long axial field-of-view (FOV) causes a parallax error not only in the radial direction but also in the axial direction. In a previous simulation study, we demonstrated that a total-body small animal PET scanner with a 4-layer depth-of-interaction (DOI) detector can reduce the parallax error substantially. In this study, we present the first imaging results with the prototype total-body small animal PET (TBSAP) scanner. The proposed TBSAP scanner has an inner diameter of 155 mm and an axial length of 325.6 mm which can cover a rat whole-body. The TBSAP consists of 6 rings each of which has 10 DOI detectors Five of 6 rings are used since the detector calibration of the 6th ring has not been finished yet. Each DOI PET detector consists of a 4-layer Zr-doped gadolinium oxyorthosilicate (GSOZ) crystal array and an 8×8 array multi-anode PMT. Each crystal layer has a 16×16 array of GSOZ crystals (2.8×2.8×7.5 mm3) which yields a total crystal thickness of 30 mm. The PMT anode signals are multiplexed using a resistive network, and then digitized by the 8-bit DAQ system (Hamamatsu, Japan). The 2.2 mm rod of the Derenzo-like phantom can be resolved even with the 30 mm radial offset. The peak sensitivity of 16.7% is obtained at the center of the FOV. The parallax error along the radial and axial directions can be reduced by using the 4-layer DOI detector. In the near future, we will perform a real-time dynamic animal imaging study with the prototype PET scanner.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2020 Virtual IEEE Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2020-11-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:58:30.700929
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3