Evaluation of neutron ambient dose equivalent in carbon-ion radiotherapy with energy scanning

https://repo.qst.go.jp/records/80830
https://repo.qst.go.jp/records/80830
8af6fba2-70ad-45d0-876e-514a383d82df
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-10-28
タイトル
タイトル Evaluation of neutron ambient dose equivalent in carbon-ion radiotherapy with energy scanning
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsumoto, Shinnosuke

× Matsumoto, Shinnosuke

WEKO 1006083

Matsumoto, Shinnosuke

Search repository
Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 1006084

Yonai, Shunsuke

Search repository
Shinnosuke, Matsumoto

× Shinnosuke, Matsumoto

WEKO 1006085

en Shinnosuke, Matsumoto

Search repository
Shunsuke, Yonai

× Shunsuke, Yonai

WEKO 1006086

en Shunsuke, Yonai

Search repository
抄録
内容記述タイプ Abstract
内容記述 In carbon-ion radiotherapy (CIRT), secondary neutrons are produced by nuclear interactions in the beamline devices or patient. Herein, the characteristics of secondary neutrons in CIRT with energy scanning (ES) were evaluated. Neutron ambient dose equivalents (H*(10)) were measured using WENDI-II. The neutron energy spectrum was calculated using the Monte Carlo simulation. Measurement and calculation were performed under realistic case scenarios using maximum beam energies (Emax) of 290, 350, and 400 MeV/u. Moreover, H*(10) in ES was compared with H*(10) in range-shifter scanning (RS) and hybrid scanning (HS). H*(10) in Emax = 290 MeV/u was 65% less than that in Emax = 400 MeV/u. At Emax = 350 MeV/u, H*(10) in ES at θ = 120 was 42% of that at θ = 60. The neutron dose in ES CIRT decreased to approximately 60% and 70% of that in RS and HS CIRT, respectively, at 50-cm distance from the beam axis.
書誌情報 Radiation Protection Dosimetry

巻 191, 号 3, p. 310-318, 発行日 2020-10
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncaa166
関連サイト
識別子タイプ URI
関連識別子 https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncaa166/5941759?searchresult=1
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:26:10.260320
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3