WEKO3
アイテム
An update of dynamic thermal-hydraulic simulations of the JT-60SA Toroidal Field coil cooling loop for preparing plasma operation
https://repo.qst.go.jp/records/80616
https://repo.qst.go.jp/records/806166bb537ad-7b58-465f-af6f-0eeeb01b4317
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-10-01 | |||||
タイトル | ||||||
タイトル | An update of dynamic thermal-hydraulic simulations of the JT-60SA Toroidal Field coil cooling loop for preparing plasma operation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Varin, S.
× Varin, S.× Bonne, F.× Hoa, C.× Nicollet, S.× Zani, L.× J.-C., Vallet× Fukui, Kazuma× Natsume, Kyohei× Kazuma, Fukui× Kyohei, Natsume |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The JT-60SA cryogenic system was commissioned in 2016 in closed loop, without the cryogenic users (superconducting magnets, current leads, thermal shields). The first plasma operation is expected in 2020. This paper updates the heat load profiles resulting from the cooling loop of TF magnets, and received by the refrigerator and its thermal damper. The heat load profiles are calculated through thermal-hydraulic simulations of the magnets and the associated cryo-distribution, also named as supercritical helium loops. This update was performed by taking into account new data from the TF magnets (measured pressure drops, updated heat loads coming from the plasma), as well as a more accurate thermal model of the TF magnet. Previous simulation had been performed using the Vincenta code in 2010 and were used for the cryogenic system acceptance tests. The new thermal-hydraulic model is performed by using Simcryogenics, the modeling tool dedicated to refrigeration and cryo-distribution developed by CEA (Commissariat à l’énergie atomique et aux énergies alternatives). The differences between the two simulation results are highlighted and analyzed. These simulations provide the pulsed heat load profiles smoothed by the cryo-distribution and deposited into the thermal damper. | |||||
書誌情報 |
Cryogenics 巻 109, p. 103092, 発行日 2020-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0011-2275 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.cryogenics.2020.103092 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/abs/pii/S0011227520300941#! |