Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement

https://repo.qst.go.jp/records/80595
https://repo.qst.go.jp/records/80595
c86538d5-fc92-4e43-9389-b199c7b21d97
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-09-30
タイトル
タイトル Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tani, Kotaro

× Tani, Kotaro

WEKO 1011330

Tani, Kotaro

Search repository
Igarashi, Yu

× Igarashi, Yu

WEKO 1011331

Igarashi, Yu

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 1011332

Eunjoo, Kim

Search repository
Iimoto, Takeshi

× Iimoto, Takeshi

WEKO 1011333

Iimoto, Takeshi

Search repository
Kurihara, Osamu

× Kurihara, Osamu

WEKO 1011334

Kurihara, Osamu

Search repository
Kotaro, Tani

× Kotaro, Tani

WEKO 1011335

en Kotaro, Tani

Search repository
Yu, Igarashi

× Yu, Igarashi

WEKO 1011336

en Yu, Igarashi

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 1011337

en Eunjoo, Kim

Search repository
Takeshi, Iimoto

× Takeshi, Iimoto

WEKO 1011338

en Takeshi, Iimoto

Search repository
Osamu, Kurihara

× Osamu, Kurihara

WEKO 1011339

en Osamu, Kurihara

Search repository
抄録
内容記述タイプ Abstract
内容記述 FASTSCAN (Canberra, Meriden, CT, USA), a standing-type whole-body counter with upper and lower NaI(Tl) detectors, has been mostly used to determine local residents’ level of internal contamination with 134/137Cs following the Fukushima Daiichi Nuclear Power Plant (FDNPP) disaster in 2011. In the present study, we performed Monte-Carlo simulations with age-specific mathematical human phantoms to investigate the counting efficiencies of the FASTSCAN counter for 131I thyroid measurements. As a result, although the lower detector had low sensitivity for 131I in the thyroids of the adult and 15 y phantoms as well as the 10 y phantom standing on a 30-cm-high stool, the response of this detector may be used as an indicator of surface contamination overlooked on a subject. The total counting efficiency investigated in this study was 0.017–0.018 (cps/Bq) among all age groups. Based on this sensitivity, the determination level for thyroid activity could be calculated to be ~300 Bq under the slightly elevated background radiation level observed after the FDNPP disaster.
書誌情報 Radiation Measurements

巻 135, p. 106335, 発行日 2020-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radmeas.2020.106335
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S1350448720300998#!
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:20:26.402182
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3