ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Development of a rapid analytical method for U, Np, and Pu using ICP-MS and ICP-MS/MS in urine samples for patient screening after radiation accident

https://repo.qst.go.jp/records/80455
https://repo.qst.go.jp/records/80455
432b3e8d-eb08-45e8-9f62-9aab4e0a78a0
Item type 会議発表用資料 / Presentation(1)
公開日 2020-09-10
タイトル
タイトル Development of a rapid analytical method for U, Np, and Pu using ICP-MS and ICP-MS/MS in urine samples for patient screening after radiation accident
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yang, Guosheng

× Yang, Guosheng

WEKO 885994

Yang, Guosheng

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 885995

Zheng, Jian

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 885996

Eunjoo, Kim

Search repository
Seno, Hatsuho

× Seno, Hatsuho

WEKO 885997

Seno, Hatsuho

Search repository
Kowatari, Munehiko

× Kowatari, Munehiko

WEKO 885998

Kowatari, Munehiko

Search repository
Kurihara, Osamu

× Kurihara, Osamu

WEKO 885999

Kurihara, Osamu

Search repository
Yang, Guosheng

× Yang, Guosheng

WEKO 886000

en Yang, Guosheng

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 886001

en Zheng, Jian

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 886002

en Eunjoo, Kim

Search repository
Seno, Hatsuho

× Seno, Hatsuho

WEKO 886003

en Seno, Hatsuho

Search repository
Kowatari, Munehiko

× Kowatari, Munehiko

WEKO 886004

en Kowatari, Munehiko

Search repository
Kurihara, Osamu

× Kurihara, Osamu

WEKO 886005

en Kurihara, Osamu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Internal contamination with alpha-particle emitting actinides, such as 238U, 237Np, 239Pu, 240Pu, is likely to bring a large radiation exposure dose to the patient even if the intake amount is small. In order to provide timely information for prompting decision making in radiation emergency medicine, we attempted to develop a simple and rapid method based on the analysis of ultra-trace level of U, 237Np and Pu isotopes in a small amount of urine samples (20–100 mL) by the SF-ICP-MS and the ICP-MS/MS. A simple single chromatographic column packed with 2 mL AG MP-1M resin (100–200 mesh, chloride form, Bio-Rad, Hercules, CA, USA) was used for the separation of targeted isotopes from the matrix elements and other potential interferences. Uranium isotopes were measured using 233U as a yield tracer with a yield of ca. 10%. To avoid polyatomic and tailing effects from U, 237Np and Pu isotopes were collected after U fraction and measured using 242Pu as a yield tracer with a yield of ca. 70%. Finally, the proposed method was applied to the contaminated urine samples during the Pu inhalation accident occured at JAEA in 2017.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 日本放射化学会第64回討論会(2020)
発表年月日
日付 2020-09-09
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:02:08.840225
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3