  1. 原著論文

Thermoluminescence studies of polycrystalline CaSiO3 pellets for photons and particle therapy beams

https://repo.qst.go.jp/records/80357
https://repo.qst.go.jp/records/80357
719e272e-1a74-40d1-befa-61413eda3b82
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-08-25
タイトル
タイトル Thermoluminescence studies of polycrystalline CaSiO3 pellets for photons and particle therapy beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Carlos, D. Gonzales-Lorenzo

× Carlos, D. Gonzales-Lorenzo

WEKO 1070565

Carlos, D. Gonzales-Lorenzo

Search repository
De Freitas, Nascimento

× De Freitas, Nascimento

WEKO 1070566

De Freitas, Nascimento

Search repository
Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 1070567

Kodaira, Satoshi

Search repository
B. Gomes, Monise

× B. Gomes, Monise

WEKO 1070568

B. Gomes, Monise

Search repository
Watanabe, Shigueo

× Watanabe, Shigueo

WEKO 1070569

Watanabe, Shigueo

Search repository
De Freitas, Nascimento

× De Freitas, Nascimento

WEKO 1070570

en De Freitas, Nascimento

Search repository
Satoshi, Kodaira

× Satoshi, Kodaira

WEKO 1070571

en Satoshi, Kodaira

Search repository
抄録
内容記述タイプ Abstract
内容記述 In this work, pellets of CaSiO3 have been produced for investigation as gamma radiation, proton, and carbon ions detector. They were then irradiated to gamma radiation using 137Cs and 60Co sources. Furthermore, pellets of CaSiO3 were exposed to 160 MeV proton and 290 MeV/n carbon ion beam from an upper synchrotron. Thermoluminescence (TL) responses of these pellets presented the same prominent peak at about 170 °C, and two possible high-temperature peaks at 270 and 320 °C when irradiated to gamma, proton, and carbon ion beam. Dose-response curve, minimum detectable dose (MDD), energy dependence, and dependence on the dose rate when irradiated with gamma radiation were evaluated in this material. Linear dose-response curves for proton and carbon ion irradiation have been compared to that of the gamma dose-response. In this way, the dose read out in Harshaw TL reader presented a good agreement with doses found using ion chamber in the case of proton beams and slightly less in the case of carbon beam due to the LET dependency. Furthermore, relative efficiencies of CaSiO3 for beam irradiation of proton and carbon ion display no dependence in the analyzed particle doses range.
書誌情報 Radiation Physics and Chemistry

巻 177, p. 109132, 発行日 2020-12
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0969-806X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radphyschem.2020.109132
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.radphyschem.2020.109132
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:44:03.155393
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3