| タイトル | Large-area perfect blackbody sheets having aperiodic array of surface micro-cavities for high-precision thermal imager calibration | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
SHIMIZU, YUHEI
× SHIMIZU, YUHEI× Koshikawa, Hiroshi× IMBE, MASATOSHI× Yamaki, Tetsuya× AMEMIYA, KUNIAKI× Koshikawa, Hiroshi× Yamaki, Tetsuya |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | We present a large-area perfect blackbody sheet, which would offer a planar standard radiator for high-precision thermal imager calibration. Polydimethylsiloxane (PDMS) sheets with nano-precision surface micro-cavity structures achieve both ultra-low reflectance (ultra-high emissivity close to unity) over the thermal infrared wavelengths and high durability to mechanical contact. The investigation on the geometrical parameters of the conical micro-cavities, that is, radii and aspect ratios (ratio of height to radius), confirmed that the PDMS blackbody sheet with a micro-cavity radius of ~6 μm and an aspect ratio of ~4 exhibits the optimum hemispherical reflectance of less than 0.002 (emissivity of higher than 0.998) at the thermal wavelengths (6–15 μm). Furthermore, the large-area PDMS blackbody sheet of 100 mm × 80 mm maintained an excellent in-plane uniformity of the emissivity. This unprecedented large-area perfect blackbody conforms to the International Electrotechnical Commission (IEC) standard recommendation regarding thermal imager calibration for fever screening in terms of the emissivity performance. | |||||
| 書誌情報 |
Optics Express 巻 28, 号 15, p. 22606-22616, 発行日 2020-07 |
|||||
| 出版者 | ||||||
| 出版者 | The Optical Society | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 1094-4087 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1364/OE.397136 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://www.osapublishing.org/oe/abstract.cfm?uri=oe-28-15-22606 | |||||