Large-area perfect blackbody sheets having aperiodic array of surface micro-cavities for high-precision thermal imager calibration

https://repo.qst.go.jp/records/80313
https://repo.qst.go.jp/records/80313
ceebfd04-8e06-4760-b4e4-037b280851d5
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-07-13
タイトル
タイトル Large-area perfect blackbody sheets having aperiodic array of surface micro-cavities for high-precision thermal imager calibration
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 SHIMIZU, YUHEI

× SHIMIZU, YUHEI

WEKO 881860

SHIMIZU, YUHEI

Search repository
Koshikawa, Hiroshi

× Koshikawa, Hiroshi

WEKO 881861

Koshikawa, Hiroshi

Search repository
IMBE, MASATOSHI

× IMBE, MASATOSHI

WEKO 881862

IMBE, MASATOSHI

Search repository
Yamaki, Tetsuya

× Yamaki, Tetsuya

WEKO 881863

Yamaki, Tetsuya

Search repository
AMEMIYA, KUNIAKI

× AMEMIYA, KUNIAKI

WEKO 881864

AMEMIYA, KUNIAKI

Search repository
Koshikawa, Hiroshi

× Koshikawa, Hiroshi

WEKO 881865

en Koshikawa, Hiroshi

Search repository
Yamaki, Tetsuya

× Yamaki, Tetsuya

WEKO 881866

en Yamaki, Tetsuya

Search repository
抄録
内容記述タイプ Abstract
内容記述 We present a large-area perfect blackbody sheet, which would offer a planar standard radiator for high-precision thermal imager calibration. Polydimethylsiloxane (PDMS) sheets with nano-precision surface micro-cavity structures achieve both ultra-low reflectance (ultra-high emissivity close to unity) over the thermal infrared wavelengths and high durability to mechanical contact. The investigation on the geometrical parameters of the conical micro-cavities, that is, radii and aspect ratios (ratio of height to radius), confirmed that the PDMS blackbody sheet with a micro-cavity radius of ~6 μm and an aspect ratio of ~4 exhibits the optimum hemispherical reflectance of less than 0.002 (emissivity of higher than 0.998) at the thermal wavelengths (6–15 μm). Furthermore, the large-area PDMS blackbody sheet of 100 mm × 80 mm maintained an excellent in-plane uniformity of the emissivity. This unprecedented large-area perfect blackbody conforms to the International Electrotechnical Commission (IEC) standard recommendation regarding thermal imager calibration for fever screening in terms of the emissivity performance.
書誌情報 Optics Express

巻 28, 号 15, p. 22606-22616, 発行日 2020-07
出版者
出版者 The Optical Society
ISSN
収録物識別子タイプ ISSN
収録物識別子 1094-4087
DOI
識別子タイプ DOI
関連識別子 10.1364/OE.397136
関連サイト
識別子タイプ URI
関連識別子 https://www.osapublishing.org/oe/abstract.cfm?uri=oe-28-15-22606
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:03:24.868160
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3