Investigation of using a long-life electronic personal dosimeter for monitoring aviation doses of frequent flyers

https://repo.qst.go.jp/records/80283
https://repo.qst.go.jp/records/80283
0c34e017-30b6-486d-8bc3-139522efb625
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-08-04
タイトル
タイトル Investigation of using a long-life electronic personal dosimeter for monitoring aviation doses of frequent flyers
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yasuda, Hiroshi

× Yasuda, Hiroshi

WEKO 881840

Yasuda, Hiroshi

Search repository
Yajima, Kazuaki

× Yajima, Kazuaki

WEKO 881841

Yajima, Kazuaki

Search repository
Sato, Tatsuhiko

× Sato, Tatsuhiko

WEKO 881842

Sato, Tatsuhiko

Search repository
Yasuda, Hiroshi

× Yasuda, Hiroshi

WEKO 881843

en Yasuda, Hiroshi

Search repository
Yajima, Kazuaki

× Yajima, Kazuaki

WEKO 881844

en Yajima, Kazuaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 For the aim of managing the in-flight cosmic radiation exposure of frequent flyers, we have investigated an application of a recently developed electronic personal dosimeter (D-shuttle) for aviation dosimetry. In four long-haul flights between Japan and Germany, it was confirmed that the D-shuttle values were in the range of 25%–30% of the total H*(10) estimated by a route-dose calculation program JISCARD EX. It was found that the values obtained with D-shuttle on the chest were nearly the same with those in a hand luggage placed under the passenger seat, while the values obtained in a suitcase which was placed in the cargo area were notably lower than those in the cabin. According to these findings, it would be possible to monitor the annual aviation doses of frequent flyers by using the D-shuttle dosimeters kept in a hand luggage. Such continuous measurements will also be useful for verification of an unpredicted additional exposure from solar energetic particles.
書誌情報 Radiation Measurements

巻 134, 発行日 2020-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 1350-4487
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radmeas.2020.106309
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S1350448720300731
戻る
0
views
See details
Views