ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Magnetic field generation system of the magnetic probe with diamond quantum sensor and ferromagnetic materials for the detection of sentinel lymph nodes with magnetic nanoparticles

https://repo.qst.go.jp/records/80229
https://repo.qst.go.jp/records/80229
3a1ff81f-7751-4fd0-8067-b06bcd97156b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-07-22
タイトル
タイトル Magnetic field generation system of the magnetic probe with diamond quantum sensor and ferromagnetic materials for the detection of sentinel lymph nodes with magnetic nanoparticles
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kitaizumi, Takahiro

× Kitaizumi, Takahiro

WEKO 1010899

Kitaizumi, Takahiro

Search repository
Kuwahata, Akihiro

× Kuwahata, Akihiro

WEKO 1010900

Kuwahata, Akihiro

Search repository
Saichi, Kota

× Saichi, Kota

WEKO 1010901

Saichi, Kota

Search repository
Sato, Takumi

× Sato, Takumi

WEKO 1010902

Sato, Takumi

Search repository
Igarashi, Ryuji

× Igarashi, Ryuji

WEKO 1010903

Igarashi, Ryuji

Search repository
Ohshima, Takeshi

× Ohshima, Takeshi

WEKO 1010904

Ohshima, Takeshi

Search repository
Masuyama, Yuta

× Masuyama, Yuta

WEKO 1010905

Masuyama, Yuta

Search repository
Iwasaki, Takayuki

× Iwasaki, Takayuki

WEKO 1010906

Iwasaki, Takayuki

Search repository
Hatano, Mutsuko

× Hatano, Mutsuko

WEKO 1010907

Hatano, Mutsuko

Search repository
Jelezko, Fedor

× Jelezko, Fedor

WEKO 1010908

Jelezko, Fedor

Search repository
Kusakabe, Moriaki

× Kusakabe, Moriaki

WEKO 1010909

Kusakabe, Moriaki

Search repository
Yatsui, Takashi

× Yatsui, Takashi

WEKO 1010910

Yatsui, Takashi

Search repository
Sekino, Masaki

× Sekino, Masaki

WEKO 1010911

Sekino, Masaki

Search repository
Ryuji, Igarashi

× Ryuji, Igarashi

WEKO 1010912

en Ryuji, Igarashi

Search repository
Takeshi, Ohshima

× Takeshi, Ohshima

WEKO 1010913

en Takeshi, Ohshima

Search repository
Yuta, Masuyama

× Yuta, Masuyama

WEKO 1010914

en Yuta, Masuyama

Search repository
Mutsuko, Hatano

× Mutsuko, Hatano

WEKO 1010915

en Mutsuko, Hatano

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have developed the magnetic probe with a diamond quantum sensor and electromagnetic coils to detect sentinel lymph nodes (SLNs), as the medical application of diamond quantum sensing. The probe magnetizes magnetic nanoparticles (MNPs) accumulated in SLNs and detect the magnetic fields of magnetized MNPs. In this study. We designed a ferromagnetic core that has a unique shape and optimized the magnetic field generation system for improving the detection performance, such as the magnetic sensitivity and detectable distance. The proposed magnetic core enhances an excitation magnetic field strength at a longer distance and suppresses a bias field strength at a location of the diamond quantum sensor. The increment of the excitation field is approximately 370% and the decrement of the bias field is approximately 45%. In addition to the proposed magnetic core, even applying a cancellation coil, the excitation field strength is ten-fold compared with the coil only structure, suggesting the larger magnetization of MNPs generates the large magnetic field for longer detectable distance.
書誌情報 IEEE Transactions on Magnetics

巻 57, 号 2, p. 5100405, 発行日 2020-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0018-9464
DOI
識別子タイプ DOI
関連識別子 10.1109/TMAG.2020.3009334
関連サイト
識別子タイプ URI
関連識別子 https://ieeexplore.ieee.org/document/9143162
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:20:53.826382
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3