ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Correction method for the energy spectrum of laser-accelerated protons measured by CR-39 track detectors with stepwise energy filters

https://repo.qst.go.jp/records/80223
https://repo.qst.go.jp/records/80223
38f9a172-5674-4134-bad0-3b488c0f773a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-07-21
タイトル
タイトル Correction method for the energy spectrum of laser-accelerated protons measured by CR-39 track detectors with stepwise energy filters
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanasaki, Masato

× Kanasaki, Masato

WEKO 1070601

Kanasaki, Masato

Search repository
Sakamoto, Keita

× Sakamoto, Keita

WEKO 1070602

Sakamoto, Keita

Search repository
Asai, Takafumi

× Asai, Takafumi

WEKO 1070603

Asai, Takafumi

Search repository
Jinno, Satoshi

× Jinno, Satoshi

WEKO 1070604

Jinno, Satoshi

Search repository
Kodaira, Satoshi

× Kodaira, Satoshi

WEKO 1070605

Kodaira, Satoshi

Search repository
Yamauchi, Tomoya

× Yamauchi, Tomoya

WEKO 1070606

Yamauchi, Tomoya

Search repository
Oda, Keiji

× Oda, Keiji

WEKO 1070607

Oda, Keiji

Search repository
Fukuda, Yuji

× Fukuda, Yuji

WEKO 1070608

Fukuda, Yuji

Search repository
Takafumi, Asai

× Takafumi, Asai

WEKO 1070609

en Takafumi, Asai

Search repository
Satoshi, Kodaira

× Satoshi, Kodaira

WEKO 1070610

en Satoshi, Kodaira

Search repository
Yuji, Fukuda

× Yuji, Fukuda

WEKO 1070611

en Yuji, Fukuda

Search repository
抄録
内容記述タイプ Abstract
内容記述 A combination of CR-39 track detectors and a stepwise energy filter is a simple method to measure the energy spectrum of laser-accelerated protons. The number of etch pits in each area of the CR-39 detector is expected to represent the energy spectrum because the different thicknesses of the filters result in different areas into which the energy reaches in CR-39. However, the higher energy regions may overlap depending on the sensitivity of CR-39. To avoid overlapping, i.e., overestimation of the number of etch pits for each energy region, a correction method for the energy spectrum from the number of etch pits was developed. Based on the calculation results of the reaching energy values and incident energy ranges for CR-39, etch pits are selected that should be counted in each area. CR-39 with stepwise energy lters provides a corrected energy spectrum of laser-accelerated protons by applying the developed method.
書誌情報 High Energy Density Physics

巻 37, p. 100852, 発行日 2020-07
出版者
出版者 Elsevier B.V.
ISSN
収録物識別子タイプ ISSN
収録物識別子 1574-1818
DOI
識別子タイプ DOI
関連識別子 10.1016/j.hedp.2020.100852
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.hedp.2020.100852
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:44:00.599717
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3