WEKO3
アイテム
Rapid Pu analysis by ICP-MS and alpha spectrometry in urine samples for patient screening after radiation accident
https://repo.qst.go.jp/records/80179
https://repo.qst.go.jp/records/801794614f16d-3988-4a86-a5b8-bb21285fcbd7
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-07-15 | |||||
タイトル | ||||||
タイトル | Rapid Pu analysis by ICP-MS and alpha spectrometry in urine samples for patient screening after radiation accident | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yang, Guosheng
× Yang, Guosheng× Zheng, Jian× Eunjoo, Kim× Seno, Hatsuho× Kurihara, Osamu× Yang, Guosheng× Zheng, Jian× Eunjoo, Kim× Hatsuho, Seno× Osamu, Kurihara |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | For the 2019 PROCORAD (Association for the PROmotion of Quality COntrol in RADiotoxicological Analysis) intercomparison campaign for urine actinides analysis, we compared SF-ICP-MS and ICP-MS/MS combined with chromatographic separation using TEVA+UTEVA+DGA resins and alpha spectrometry combined with chromatographic separation using TEVA resin for the measurement of 239Pu. The Pu yields were in the range of 68–93 % (n=20). Both the methods of SF-ICP-MS (2.44±0.05 mBq/sample for 19 ACTA, n=4 and 7.63±0.13 mBq/sample for 19 ACTB, n=4) and ICP-MS/MS (2.45±0.21 mBq/sample for 19 ACTA, n=1 and 7.89±0.54 mBq/sample for 19 ACTB, n=1) presented precise and accurate results that agreed well with the assigned values (2.52±0.26 mBq/sample for 19 ACTA and 7.56±0.39 mBq/sample for 19 ACTB). The method of alpha spectrometry, showing larger uncertainties, also presented comparable results (3.49±1.29 mBq/sample for 19 ACTA, n=1 and 8.05±1.76 mBq/sample for 19 ACTB, n=1). Due to the high sensitivity of SF-ICP-MS and ICP-MS/MS, rapid determination of 239Pu (ca. 10 h) can be achieved in small volume urine sample (20 mL) generally. In contrast, the method of alpha spectrometry generally consumes more sample (e.g. 500 mL) and is more time-consuming. Therefore, it would be more feasible to measure long-lived 239Pu and 240Pu by the methods of SF-ICP-MS and ICP-MS/MS, and short-lived 238Pu by the method of alpha spectrometry for emergency response. | |||||
書誌情報 |
Proceedings of the 21th Workshop on Environmental Radioactivity (KEK proceedings) p. 163-169, 発行日 2020-11 |
|||||
出版者 | ||||||
出版者 | High Energy accelerator Research Organization (KEK) |