Experimental Determination of Anisotropic Emission of Neutrons From 252Cf Neutron Source with the Spherical Protection Case

https://repo.qst.go.jp/records/80157
https://repo.qst.go.jp/records/80157
95a4ed0c-7d77-454e-b83e-60eb6e229fd9
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-07-06
タイトル
タイトル Experimental Determination of Anisotropic Emission of Neutrons From 252Cf Neutron Source with the Spherical Protection Case
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kowatari, Munehiko

× Kowatari, Munehiko

WEKO 879266

Kowatari, Munehiko

Search repository
Nishino, Sho

× Nishino, Sho

WEKO 879267

Nishino, Sho

Search repository
Marie D Romallosa, Kristine

× Marie D Romallosa, Kristine

WEKO 879268

Marie D Romallosa, Kristine

Search repository
Yoshitomi, Hiroshi

× Yoshitomi, Hiroshi

WEKO 879269

Yoshitomi, Hiroshi

Search repository
Tanimura, Yoshihiko

× Tanimura, Yoshihiko

WEKO 879270

Tanimura, Yoshihiko

Search repository
Ohishi, Tetsuya

× Ohishi, Tetsuya

WEKO 879271

Ohishi, Tetsuya

Search repository
Kowatari, Munehiko

× Kowatari, Munehiko

WEKO 879272

en Kowatari, Munehiko

Search repository
抄録
内容記述タイプ Abstract
内容記述 The anisotropic emission of neutrons from a cylindrical X1 252Cf source with the spherical external casing was experimentally determined. The influence of metal materials and shapes of the external casing to the anisotropy factor, FI(θ), was assessed by the Monte Carlo calculation, before performing the measurement. The results of the calculation implied that light- and spherical-shaped external casing decreases the anisotropic emission of neutrons from a cylindrical source and the nature of the material does not affect the anisotropic emission to a large extent. The experimental results obtained when a spherical-shaped aluminum protection case was employed also revealed that the anisotropy factor was close to 1.0 with a wide zenith angle range. Considering the source handling and measures against mechanical impact to the source, we designed an SUS304-made spherical protection case for a renovated source delivering apparatus. With the SUS304-made spherical protection case, the measured anisotropy factor FI(90) was determined to be 1.002 ± 0.002 (k = 1). Results from the experiments also indicated that the measured anisotropy factor has a flat distribution from 55 to 125° with zenith angle.
書誌情報 Radiation Protection Dosimetry

巻 189, 号 4, p. 436-443, 発行日 2020-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncaa064
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1093/rpd/ncaa064
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:04:16.381318
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3