  1. 原著論文

Discussions on Tritiated Water Treatment for Fukushima Daiichi Nuclear Power Station

https://repo.qst.go.jp/records/80144
https://repo.qst.go.jp/records/80144
19abf3b2-154e-4678-b862-8464d834e0c8
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-07-01
タイトル
タイトル Discussions on Tritiated Water Treatment for Fukushima Daiichi Nuclear Power Station
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamanishi, Toshihiko

× Yamanishi, Toshihiko

WEKO 878592

Yamanishi, Toshihiko

Search repository
Kakiuchi, Hideki

× Kakiuchi, Hideki

WEKO 878593

Kakiuchi, Hideki

Search repository
Tauchi, Hiroshi

× Tauchi, Hiroshi

WEKO 878594

Tauchi, Hiroshi

Search repository
Yamamoto, Tokuhiro

× Yamamoto, Tokuhiro

WEKO 878595

Yamamoto, Tokuhiro

Search repository
Yamamoto, Ichiro

× Yamamoto, Ichiro

WEKO 878596

Yamamoto, Ichiro

Search repository
Yamanishi, Toshihiko

× Yamanishi, Toshihiko

WEKO 878597

en Yamanishi, Toshihiko

Search repository
Kakiuchi, Hideki

× Kakiuchi, Hideki

WEKO 878598

en Kakiuchi, Hideki

Search repository
抄録
内容記述タイプ Abstract
内容記述 A series of discussions on tritiated water of the Fukushima Daiichi Nuclear Power Station (FD-NPS) was carried out. A large amount of contaminated water has been generated in FD-NPS. Radioisotopes in the contaminated water have been removed except tritium, and thus, tritiated water has been left and stored. As of March 2019, 1 126 500 m3 of tritiated water has been stored in tanks. The average tritium concentration in the tritiated water is 1000 Bq/cm3.

Various options for handling the tritiated water, such as discharge into the sea, geosphere injection, underground burial, and vapor or hydrogen release with and without pretreatment, were discussed on the basis that there is no scientific impact on people. Through the discussions, 11 options for handling tritiated water were summarized. At the same time, some experimental tests of tritium separation (with small-scale and/or full-scale component test stands) were also carried out. As a result, it was concluded that the tested separation technologies could not yet be applied to the case of FD-NPS. No selection from the 11 options has yet been recommended, and further discussions for the tritiated water have continued with public hearings.
書誌情報 Fusion Science and Technology

巻 76, 号 4, p. 430-438, 発行日 2020-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 1536-1055
DOI
識別子タイプ DOI
関連識別子 10.1080/15361055.2020.1716454
関連サイト
識別子タイプ URI
関連識別子 https://www.tandfonline.com/doi/full/10.1080/15361055.2020.1716454
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:04:32.074580
Show All versions

Share

Mendeley Twitter Facebook Print Addthis