ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Experimental investigation of the characteristics of radioactive beams for heavy ion therapy

https://repo.qst.go.jp/records/80143
https://repo.qst.go.jp/records/80143
9dc8cfc7-8a5a-4611-879f-f23dfa7b47c4
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-07-01
タイトル
タイトル Experimental investigation of the characteristics of radioactive beams for heavy ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Chacon, Andrew

× Chacon, Andrew

WEKO 928733

Chacon, Andrew

Search repository
James, Benjamin

× James, Benjamin

WEKO 928734

James, Benjamin

Search repository
Linh Tran, Thuy

× Linh Tran, Thuy

WEKO 928735

Linh Tran, Thuy

Search repository
Guatelli, Susanna

× Guatelli, Susanna

WEKO 928736

Guatelli, Susanna

Search repository
Chartier, Lachlan

× Chartier, Lachlan

WEKO 928737

Chartier, Lachlan

Search repository
Prokopvich, Dale

× Prokopvich, Dale

WEKO 928738

Prokopvich, Dale

Search repository
R. Franklin, Daniel

× R. Franklin, Daniel

WEKO 928739

R. Franklin, Daniel

Search repository
Mohammadi, Akram

× Mohammadi, Akram

WEKO 928740

Mohammadi, Akram

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 928741

Nishikido, Fumihiko

Search repository
Iwao, Yuma

× Iwao, Yuma

WEKO 928742

Iwao, Yuma

Search repository
Akamatsu, Go

× Akamatsu, Go

WEKO 928743

Akamatsu, Go

Search repository
Takyu, Sodai

× Takyu, Sodai

WEKO 928744

Takyu, Sodai

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 928745

Tashima, Hideaki

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 928746

Yamaya, Taiga

Search repository
Parodi, Katia

× Parodi, Katia

WEKO 928747

Parodi, Katia

Search repository
Rosenfeld, Anatoly

× Rosenfeld, Anatoly

WEKO 928748

Rosenfeld, Anatoly

Search repository
Mitra, Safavi‐Naeini

× Mitra, Safavi‐Naeini

WEKO 928749

Mitra, Safavi‐Naeini

Search repository
Linh Tran, Thuy

× Linh Tran, Thuy

WEKO 928750

en Linh Tran, Thuy

Search repository
Lachlan, Chartier

× Lachlan, Chartier

WEKO 928751

en Lachlan, Chartier

Search repository
Mohammadi, Akram

× Mohammadi, Akram

WEKO 928752

en Mohammadi, Akram

Search repository
Fumihiko, Nishikido

× Fumihiko, Nishikido

WEKO 928753

en Fumihiko, Nishikido

Search repository
Yuma, Iwao

× Yuma, Iwao

WEKO 928754

en Yuma, Iwao

Search repository
Go, Akamatsu

× Go, Akamatsu

WEKO 928755

en Go, Akamatsu

Search repository
Sodai, Takyu

× Sodai, Takyu

WEKO 928756

en Sodai, Takyu

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 928757

en Hideaki, Tashima

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 928758

en Taiga, Yamaya

Search repository
Parodi, Katia

× Parodi, Katia

WEKO 928759

en Parodi, Katia

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose
This work has two related objectives. The first is to estimate the relative biological effectiveness of two radioactive heavy ion beams based on experimental measurements, and compare these to the relative biological effectiveness of corresponding stable isotopes to determine whether they are therapeutically equivalent. The second aim is to quantitatively compare the quality of images acquired postirradiation using an in‐beam whole‐body positron emission tomography scanner for range verification quality assurance.

Methods
The energy deposited by monoenergetic beams of urn:x-wiley:00942405:media:mp14177:mp14177-math-0001C at 350 MeV/u, urn:x-wiley:00942405:media:mp14177:mp14177-math-0002O at 250 MeV/u, urn:x-wiley:00942405:media:mp14177:mp14177-math-0003C at 350 MeV/u, and urn:x-wiley:00942405:media:mp14177:mp14177-math-0004O at 430 MeV/u was measured using a cruciform transmission ionization chamber in a water phantom at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Dose‐mean lineal energy was measured at various depths along the path of each beam in a water phantom using a silicon‐on‐insulator mushroom microdosimeter. Using the modified microdosimetric kinetic model, the relative biological effectiveness at 10% survival fraction of the radioactive ion beams was evaluated and compared to that of the corresponding stable ions along the path of the beam. Finally, the postirradiation distributions of positron annihilations resulting from the decay of positron‐emitting nuclei were measured for each beam in a gelatin phantom using the in‐beam whole‐body positron emission tomography scanner at HIMAC. The depth of maximum positron‐annihilation density was compared with the depth of maximum dose deposition and the signal‐to‐background ratios were calculated and compared for images acquired over 5 and 20 min postirradiation of the phantom.

Results
In the entrance region, the urn:x-wiley:00942405:media:mp14177:mp14177-math-0005 was 1.2 ± 0.1 for both urn:x-wiley:00942405:media:mp14177:mp14177-math-0006C and urn:x-wiley:00942405:media:mp14177:mp14177-math-0007C beams, while for urn:x-wiley:00942405:media:mp14177:mp14177-math-0008O and urn:x-wiley:00942405:media:mp14177:mp14177-math-0009O it was 1.4 ± 0.1 and 1.3 ± 0.1, respectively. At the Bragg peak, the urn:x-wiley:00942405:media:mp14177:mp14177-math-0010 was 2.7 ± 0.4 for urn:x-wiley:00942405:media:mp14177:mp14177-math-0011C and 2.9 ± 0.4 for urn:x-wiley:00942405:media:mp14177:mp14177-math-0012C, while for urn:x-wiley:00942405:media:mp14177:mp14177-math-0013O and urn:x-wiley:00942405:media:mp14177:mp14177-math-0014O it was 2.7 ± 0.4 and 2.8 ± 0.4, respectively. In the tail region, urn:x-wiley:00942405:media:mp14177:mp14177-math-0015 could only be evaluated for carbon; the urn:x-wiley:00942405:media:mp14177:mp14177-math-0016 was 1.6 ± 0.2 and 1.5 ± 0.1 for urn:x-wiley:00942405:media:mp14177:mp14177-math-0017C and urn:x-wiley:00942405:media:mp14177:mp14177-math-0018C, respectively. Positron emission tomography images obtained from gelatin targets irradiated by radioactive ion beams exhibit markedly improved signal‐to‐background ratios compared to those obtained from targets irradiated by nonradioactive ion beams, with 5‐fold and 11‐fold increases in the ratios calculated for the urn:x-wiley:00942405:media:mp14177:mp14177-math-0019O and urn:x-wiley:00942405:media:mp14177:mp14177-math-0020C images compared with the values obtained for urn:x-wiley:00942405:media:mp14177:mp14177-math-0021O and urn:x-wiley:00942405:media:mp14177:mp14177-math-0022C, respectively. The difference between the depth of maximum dose and the depth of maximum positron annihilation density is 2.4 ± 0.8 mm for urn:x-wiley:00942405:media:mp14177:mp14177-math-0023C, compared to −5.6 ± 0.8 mm for urn:x-wiley:00942405:media:mp14177:mp14177-math-0024C and 0.9 ± 0.8 mm for urn:x-wiley:00942405:media:mp14177:mp14177-math-0025O vs −6.6 ± 0.8 mm for urn:x-wiley:00942405:media:mp14177:mp14177-math-0026O.

Conclusions
The urn:x-wiley:00942405:media:mp14177:mp14177-math-0027 values for urn:x-wiley:00942405:media:mp14177:mp14177-math-0028C and urn:x-wiley:00942405:media:mp14177:mp14177-math-0029O were found to be within the 95% confidence interval of the RBEs estimated for their corresponding stable isotopes across each of the regions in which it was evaluated. Furthermore, for a given dose, urn:x-wiley:00942405:media:mp14177:mp14177-math-0030C and urn:x-wiley:00942405:media:mp14177:mp14177-math-0031O beams produce much better quality images for range verification compared with urn:x-wiley:00942405:media:mp14177:mp14177-math-0032C and urn:x-wiley:00942405:media:mp14177:mp14177-math-0033O, in particular with regard to estimating the location of the Bragg peak.
書誌情報 Medical Physics

巻 47, 号 7, p. 3123-3132, 発行日 2020-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-2405
DOI
識別子タイプ DOI
関連識別子 10.1002/mp.14177
関連サイト
識別子タイプ URI
関連識別子 https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/mp.14177
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:47:49.158606
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3