Influence of momentum acceptance on range monitoring of 11C and 15O ion beams using in-beam PET

https://repo.qst.go.jp/records/80070
https://repo.qst.go.jp/records/80070
43b2bdb3-4f1a-4d85-8f21-2bfd5807998b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-06-16
タイトル
タイトル Influence of momentum acceptance on range monitoring of 11C and 15O ion beams using in-beam PET
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mohammadi, Akram

× Mohammadi, Akram

WEKO 916888

Mohammadi, Akram

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 916889

Tashima, Hideaki

Search repository
Iwao, Yuma

× Iwao, Yuma

WEKO 916890

Iwao, Yuma

Search repository
Takyu, Sodai

× Takyu, Sodai

WEKO 916891

Takyu, Sodai

Search repository
Akamatsu, Go

× Akamatsu, Go

WEKO 916892

Akamatsu, Go

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 916893

Kang, Hangyu

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 916894

Nishikido, Fumihiko

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 916895

Yoshida, Eiji

Search repository
Chacon, Andrew

× Chacon, Andrew

WEKO 916896

Chacon, Andrew

Search repository
Safavi naeini, Mitra

× Safavi naeini, Mitra

WEKO 916897

Safavi naeini, Mitra

Search repository
Parodi, Katia

× Parodi, Katia

WEKO 916898

Parodi, Katia

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 916899

Yamaya, Taiga

Search repository
Mohammadi, Akram

× Mohammadi, Akram

WEKO 916900

en Mohammadi, Akram

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 916901

en Tashima, Hideaki

Search repository
Iwao, Yuma

× Iwao, Yuma

WEKO 916902

en Iwao, Yuma

Search repository
Takyu, Sodai

× Takyu, Sodai

WEKO 916903

en Takyu, Sodai

Search repository
Akamatsu, Go

× Akamatsu, Go

WEKO 916904

en Akamatsu, Go

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 916905

en Kang, Hangyu

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 916906

en Nishikido, Fumihiko

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 916907

en Yoshida, Eiji

Search repository
Chacon, Andrew

× Chacon, Andrew

WEKO 916908

en Chacon, Andrew

Search repository
Safavi naeini, Mitra

× Safavi naeini, Mitra

WEKO 916909

en Safavi naeini, Mitra

Search repository
Parodi, Katia

× Parodi, Katia

WEKO 916910

en Parodi, Katia

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 916911

en Yamaya, Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 In heavy-ion therapy, the stopping position of primary ions in tumours needs to be monitored for effective treatment and to prevent overdose exposure to normal tissues. Positron-emitting ion beams, such as 11C and 15O, have been suggested for range verification in heavy-ion therapy using in-beam positron emission tomography (PET) imaging, which offers the capability of visualizing the ion stopping position with a high signal-to-noise ratio. We have previously demonstrated the feasibility of in-beam PET imaging for the range verification of 11C and 15O ion beams and observed a slight shift between the beam stopping position and the dose peak position in simulations, depending on the initial beam energy spread. In this study, we focused on the experimental confirmation of the shift between the Bragg peak position and the position of the maximum detected positron-emitting fragments via a PET system for positron-emitting ion beams of 11C (210 MeV u−1) and 15O (312 MeV u−1) with momentum acceptances of 5% and 0.5%. For this purpose, we measured the depth doses and performed in-beam PET imaging using a polymethyl methacrylate (PMMA) phantom for both beams with different momentum acceptances. The shifts between the Bragg peak position and the PET peak position in an irradiated PMMA phantom for the 15O ion beams were 1.8 mm and 0.3 mm for momentum acceptances of 5% and 0.5%, respectively. The shifts between the positions of two peaks for the 11C ion beam were 2.1 mm and 0.1 mm for momentum acceptances of 5% and 0.5%, respectively. We observed larger shifts between the Bragg peak and the PET peak positions for a momentum acceptance of 5% for both beams, which is consistent with the simulation results reported in our previous study. The biological doses were also estimated from the calculated relative biological effectiveness (RBE) values using a modified microdosimetric kinetic model (mMKM) and Monte Carlo simulation. Beams with a momentum acceptance of 5% should be used with caution for therapeutic applications to avoid extra dose to normal tissues beyond the tumour when the dose distal fall-off is located beyond the treatment volume.
書誌情報 Physics in Medicine & Biology

巻 65, 号 12, p. 125006-1-125006-11, 発行日 2020-06
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
PubMed番号
識別子タイプ PMID
関連識別子 32176873
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ab8059
関連サイト
識別子タイプ URI
関連識別子 https://dx.doi.org/10.1088/1361-6560/ab8059
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:51:58.925827
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3