  1. 原著論文

Measurement of ambient gamma dose rate in Metro Manila, Philippines, using a portable NaI(TI) scintillation survey meter

https://repo.qst.go.jp/records/80068
https://repo.qst.go.jp/records/80068
d62ef354-be0f-4eee-9533-f9abbb94b89f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-06-15
タイトル
タイトル Measurement of ambient gamma dose rate in Metro Manila, Philippines, using a portable NaI(TI) scintillation survey meter
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 R. Encabo, Rosario

× R. Encabo, Rosario

WEKO 872243

R. Encabo, Rosario

Search repository
Tristan F. Cruz, Paolo

× Tristan F. Cruz, Paolo

WEKO 872244

Tristan F. Cruz, Paolo

Search repository
Antonio C. Bonga III

× Antonio C. Bonga III

WEKO 872245

Antonio C. Bonga III

Search repository
L. Dela Sada, Christian

× L. Dela Sada, Christian

WEKO 872246

L. Dela Sada, Christian

Search repository
J. Omandam, Vanessa

× J. Omandam, Vanessa

WEKO 872247

J. Omandam, Vanessa

Search repository
U. Olivares, Juanario

× U. Olivares, Juanario

WEKO 872248

U. Olivares, Juanario

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 872249

Iwaoka, Kazuki

Search repository
P. Feliciano, Chitho

× P. Feliciano, Chitho

WEKO 872250

P. Feliciano, Chitho

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 872251

en Iwaoka, Kazuki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Radiological data such as ambient dose equivalent rate obtained from radiation monitoring in Metro Manila are useful for the detection of any anomalous increase of radiation dose rate levels due to nuclear or radiological mergencies. In this study, ambient dose equivalent rates were measured in different locations in Metro Manila using a portable NaI(Tl) scintillation survey meter to determine the background radiation levels within the capital. Ambient dose equivalent rates measured range from 32.7 ± 2.2 to 59.3 ± 8.7 nanosieverts per hour (nSv/h) with computed mean and median values of 41.7 and 39.6 nSv/h, respectively. These values were lower than the Philippines’ average dose rate which is 52 nanograys per hour (nGy/h). No significant trend was also observed in the monthly variation of ambient dose equivalent rate for most locations, with the dose rates being relatively consistent throughout a year. No significant trend was further observed in the monthly variation of ambient dose equivalent rate for the whole MetroManila. Data obtained in this studywere used to develop a dose rate distribution map of Metro Manila which could be used as a baseline reference of emergency responders for environmental radioactivity monitoring during nuclear or radiological emergencies that may affect Metro Manila.
書誌情報 Environmental Monitoring and Assessment

巻 192, p. 400-1, 発行日 2020-06
出版者
出版者 Springer
ISSN
収録物識別子タイプ ISSN
収録物識別子 0167-6369
DOI
識別子タイプ DOI
関連識別子 10.1007/s10661-020-08361-8
関連サイト
識別子タイプ URI
関連識別子 https://link.springer.com/article/10.1007/s10661-020-08361-8#citeas
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:06:27.833169
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3