ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Lung dose estimation of 222Rn and 220Rn progeny based in IMBA Professional software

https://repo.qst.go.jp/records/80067
https://repo.qst.go.jp/records/80067
bba9c6aa-aeed-4182-ad96-5886dc7bd8dc
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-06-15
タイトル
タイトル Lung dose estimation of 222Rn and 220Rn progeny based in IMBA Professional software
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hu, Jun

× Hu, Jun

WEKO 874387

Hu, Jun

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 874388

Iwaoka, Kazuki

Search repository
Hosoda, Masahiro

× Hosoda, Masahiro

WEKO 874389

Hosoda, Masahiro

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 874390

Tokonami, Shinji

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 874391

en Iwaoka, Kazuki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Radiation doses associated with exposures to 222Rn (radon) and 220Rn (thoron) are primarily due to inhalation of their short-lived progeny instead of the gas. The dosimetric data of radon are commonly used to assess the risk of radon-induced lung cancer derived from epidemiological studies of underground miners and from residential pooled analyzes. For estimation of the lung dose due to radon and thoron progeny, the dose conversion factor, which is the ratio of the activity concentration or PAEC of the decay products and dose is needed. There are three commonly used internal dosimetric software RADEP, LUDEP, and IMBA, which can be competent to implement to most of the biokinetic and dosimetric models recommended by ICRP to deduce the dose conversion factor and moreover to estimate the lung dose. Although all of the three internal dosimetric software use the same dosimetric model recommended by ICRP, due to the different data handling techniques, there are minor differences between the estimation results of the internal dose. There were several researchers who used the RADEP and LUDEP to conduct the dose calculation of lung dose of radon and thoron, but fewer researches gave the effective dose coefficient especially on IMBA. In this research, therefore, the dose conversion factor based on IMBA was calculated based on the reference parameters provided by the ICRP 66 and 137 and was compared with the published value of RADEP and LUDEP.
書誌情報 Radiation Environment and Medicine

巻 9, p. 21-27, 発行日 2020-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 2423-9097
関連サイト
識別子タイプ URI
関連識別子 http://crss.hirosaki-u.ac.jp/wp-content/files_mf/158333044704_REM91_Jun.Hu.pdf
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:05:49.498012
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3