WEKO3
アイテム
Efficiency and timing performance of time-of-flight detector utilizing thin foils and crossed static electric and magnetic fields for mass measurements with Rare-RI Ring facility
https://repo.qst.go.jp/records/80046
https://repo.qst.go.jp/records/8004664851836-35e4-4f40-bd53-72f1235f10cb
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-06-10 | |||||
タイトル | ||||||
タイトル | Efficiency and timing performance of time-of-flight detector utilizing thin foils and crossed static electric and magnetic fields for mass measurements with Rare-RI Ring facility | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Suzuki, Shinji
× Suzuki, Shinji× Ozawa, Akira× Kamioka, Daiki× Abe, Yasushi× Amano, Masamichi× Arakawa, Hiroki× Ge, Zhuang× Hiraishi, Kentaro× Ichikawa, Yukina× Inomata, Kumi× Kitagawa, Atsushi× Kobayashi, Takaaki× Fu Li, Hong× Matsumoto, Takuya× Moriguchi, Tetsuaki× Mukai, Momo× Nagae, Daisuke× Naimi, Sarah× Omika, Shunichiro× Sato, Shinji× Suzuki, Shinji× Ozawa, Akira× Kamioka, Daiki× Abe, Yasushi× Masamichi, Amano× Arakawa, Hiroki× Zhuang, Ge× Hiraishi, Kentaro× Inomata, Kumi× Kitagawa, Atsushi× Kobayashi, Takaaki× Matsumoto, Takuya× Moriguchi, Tetsuaki× Mukai, Momo× Nagae, Daisuke× Sato, Shinji |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We developed a time-of-flight (TOF) detector for mass measurements of rare radioactive isotopes (RIs) with a storage ring, called the Rare-RI Ring, in RIKEN. For successful mass measurements, a time resolution of less than 100 ps and a detection efficiency close to 100% are required. Additionally, the change of ion velocity in the detector should be as small as possible ( ). To satisfy these requirements, the TOF detector utilizes ion-induced secondary electrons emitted from a thin foil and the crossed static electric and magnetic fields to transport the electrons isochronously to the microchannel plate detectors. The TOF detector was tested in both offline test with an alpha source and online test with heavy ions. In the online test with 84Kr ions of 200 MeV/nucleon, a time resolution of 38.6(2) ps in sigma and a position-averaged detection efficiency of 95.2(2)% were achieved in the entire area of 45-mm-diameter aluminum-coated Mylar foil. This good performance is attributed to the electromagnetic field achieved, which is the strongest thus far for a detector with this design. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 巻 965, 発行日 2020-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nima.2020.163807 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0168900220303314 |