Sensitivity and linearity of optical fiber-based neutron detectors using small 6Li-based scintillators
https://repo.qst.go.jp/records/80023
https://repo.qst.go.jp/records/80023501a42bd-cd36-4e21-80cc-2b5feca5be3d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-06-09 | |||||
タイトル | ||||||
タイトル | Sensitivity and linearity of optical fiber-based neutron detectors using small 6Li-based scintillators | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ishikawa, Akihisa
× Ishikawa, Akihisa× Yamazaki, Atsushi× Watanabe, Kenichi× Yoshihashi, Sachiko× Uritani, Akira× Fukuda, Kentaro× Koike, Akifumi× Ogawara, Ryo× Suda, Mitsuru× Hamano, Tsuyoshi× Ogawara, Ryo× Suda, Mitsuru× Hamano, Tsuyoshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We developed optical fiber-based neutron detectors that use small pieces of 6Li-based scintillators, namely, Eu:LiCaAlF6 crystals and LiF/Eu:CaF2 eutectics. Considering that these elements have high light yields (more than 10,000 photons/neutron), they can produce pulse height spectra with clear peaks even when using optical fiber light guides. To adjust the neutron sensitivity, we controlled the amount of 6Li in the scintillator. We fabricated three different detectors using Eu:LiCaAlF6 and LiF/Eu:CaF2 with various amounts of 6Li and then evaluated the neutron sensitivity of each detector. This approach confirmed that there was a linear relationship between the neutron sensitivity and amount of 6Li, thus implying that the 6Li mass measured by a high-precision balance could be a good metric of neutron sensitivity. We also checked the linearity of the output of the detector at relatively high neutron fluxes by using an accelerator-based neutron source. Although the detectors showed saturation behavior at high count rate, we were able to cover a relatively wide dynamic range by combining multiple detectors using different amounts of 6Li. After correcting for the pulse height distortion and count loss due to pile-up events, we were able to confirm the linearity of the detectors up to a count rates of 100 kcps. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 巻 954, 発行日 2020-02 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nima.2018.11.120 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S016890021831773X |