Simple and sensitive determination of radium-226 in river water by single column-chromatographic separation coupled to SF-ICP-MS analysis in medium resolution mode.

https://repo.qst.go.jp/records/79985
https://repo.qst.go.jp/records/79985
e8487a27-3041-4163-9ba8-e9becff53677
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-03-05
タイトル
タイトル Simple and sensitive determination of radium-226 in river water by single column-chromatographic separation coupled to SF-ICP-MS analysis in medium resolution mode.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yang, Guosheng

× Yang, Guosheng

WEKO 871529

Yang, Guosheng

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 871530

Zheng, Jian

Search repository
Tagami, Keiko

× Tagami, Keiko

WEKO 871531

Tagami, Keiko

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 871532

Uchida, Shigeo

Search repository
Zhang, Jing

× Zhang, Jing

WEKO 871533

Zhang, Jing

Search repository
Wang, Jinlong

× Wang, Jinlong

WEKO 871534

Wang, Jinlong

Search repository
Du, Jinzhou

× Du, Jinzhou

WEKO 871535

Du, Jinzhou

Search repository
Yang, Guosheng

× Yang, Guosheng

WEKO 871536

en Yang, Guosheng

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 871537

en Zheng, Jian

Search repository
Tagami, Keiko

× Tagami, Keiko

WEKO 871538

en Tagami, Keiko

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 871539

en Uchida, Shigeo

Search repository
抄録
内容記述タイプ Abstract
内容記述 This article describes a novel and simple method to measure ultra-trace 226Ra in river water samples at fg L-1 (mBq L-1) levels as a means for surveying 226Ra survey in an unintended contamination in river water,. To simplify the procedure, a single column was used for separation and purification; 10 mL of AG 50W-X8 resin was packed into a 10 mL Eppendorf pipette tip, which was used as a separation column. A 500 mL sample solution was loaded, and interference elements were removed with 80 mL 4 M HCl in 20% ethanol. Subsequently, Ra together with Ba was eluted by 20 mL 5 M HNO3 prior to SF-ICP-MS analysis; this allows the naturally existing Ba in water samples to be employed as a yield tracer for 226Ra analysis. An extremely low detection limit (0.46 fg L-1 or 0.02 mBq L-1) was achieved by this method. Finally, the developed technique was applied to analyze natural water samples collected from Japanese rivers, in which the 226Ra concentrations varied in the range of 0.7 – 49.6 fg L-1 (0.03 – 1.82 mBq L-1).
書誌情報 Journal of Environmental Radioactivity

巻 220-221, 発行日 2020-05
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0265-931X
DOI
識別子タイプ DOI
関連識別子 10.1016/j.jenvrad.2020.106305
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0265931X20301788
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:06:37.596687
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3