WEKO3
アイテム
Compact Thomson parabola spectrometer with variability of energy range and measurability of angular distribution for low-energy laser-driven accelerated ions
https://repo.qst.go.jp/records/79962
https://repo.qst.go.jp/records/799622a180314-d5df-4b57-9f69-da956156ba45
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-05-18 | |||||
タイトル | ||||||
タイトル | Compact Thomson parabola spectrometer with variability of energy range and measurability of angular distribution for low-energy laser-driven accelerated ions | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
小島, 完興
× 小島, 完興× タンフン, ヂン× 長谷川, 登× 森, 道昭× 榊, 泰直× 近藤, 康太郎× Nishikino, Masaharu× Kondo, Kiminori× Kojima, Sadaoki× Dinh, Thanhhung× Hasegawa, Noboru× Mori, Michiaki× Sakaki, Hironao× Kondo, Kotaro× Nishikino, Masaharu× Kondo, Kiminori |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This article reports the development of a compact Thomson parabola spectrometer for laser-accelerated ions that can measure angular distribution with a high energy resolution and has a variable measurable energy range. The angular-resolved energy spectra for different ion species can be measured in a single shot, and the sampling angle can be selected from outside the vacuum region. The electric and magnetic fields are applied to the ion dispersion by using a permanent magnetic circuit and annulus sector-shaped electrodes with a wedge configuration. The compact magnetic circuit consists of permanent magnets, fixed yokes, and movable yokes. The magnetic flux is intentionally leaked to the movable yokes, allowing the magnetic field to be adjusted from 53 mT to 259 mT. The annulus sector-shaped electrodes with a wedge configuration provide better trace separation for high-energy ions, retain the lower-energy part of the ion signal, and subject ions passing through all pinholes to an equivalent Lorentz force. The magnetic and electric fields are designed for measuring protons and carbon ions with an energy range of 0.1–5 MeV. The spectrometer allows for the adjustment of the observable energy range afterward according to the parameters of the accelerated ion. | |||||
書誌情報 |
Review of Scientific Instruments 巻 91, p. 1-11, 発行日 2020-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0034-6748 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/5.0005450 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://aip.scitation.org/doi/10.1063/5.0005450 |