WEKO3
アイテム
Chemical Separation of Uranium and Precise Measurement of 234U/238U and 235U/238U Ratios in Soil Samples Using Multi Collector Inductively Coupled Plasma Mass Spectrometry
https://repo.qst.go.jp/records/79951
https://repo.qst.go.jp/records/79951bdf051b4-224a-4c99-8779-3606a9220e49
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-05-12 | |||||
タイトル | ||||||
タイトル | Chemical Separation of Uranium and Precise Measurement of 234U/238U and 235U/238U Ratios in Soil Samples Using Multi Collector Inductively Coupled Plasma Mass Spectrometry | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nimelan, Veerasamy
× Nimelan, Veerasamy× Takamasa, Asako× Murugan, Rajamanickam× Kasar, Sharayu× Aono, Tatsuo× Inoue, Kazumasa× Fukushi, Masahiro× Kumar Sahoo, Sarata× Nimelan, Veerasamy× Asako, Takamasa× Murugan, Rajamanickam× Kasar, Sharayu× Tatsuo, Aono× Sahoo, Sarata |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A new chemical separation has been developed to isolate uranium (U) using two UTEVA columns to minimize iron and thorium interferences from high background area soil samples containing minerals like monazites and ilmenite. The separation method was successfully verified in some certified reference materials (CRMs), for example, JSd-2, JLk-1, JB-1 and JB-3. The same method was applied for purification of U in Fukushima soil samples affected by the Fukushima dai-ichi nuclear power station (FDNPS) accident. Precise and accurate measurement of 234U/238U and 235U/238U isotope ratios in chemically separated U were carried out using a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS). In this mass spectrometric method, an array of two Faraday cups (10e11 Ω, 10e12 Ω resistor) and a Daly detector were simultaneously employed. The precision of U isotope ratios in an in-house standard was evaluated by replicate measurement. Relative standard deviation (RSD) of 234U/238U and 235U/238U were found to be 0.094% (2σ) and 0.590% (2σ), respectively. This method has been validated using a standard reference material SRM 4350B, sediment sample. The replicate measurements of 234U/238U in SRM shows 0.7% (RSD). This developed method is suitable for separation of U and its isotope ratio measurement in environmental samples. |
|||||
書誌情報 |
Molecules 巻 25, 号 9, p. 1-18, 発行日 2020-05 |
|||||
出版者 | ||||||
出版者 | MDPI | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1420-3049 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3390/molecules25092138 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.mdpi.com/1420-3049/25/9/2138 |