ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Chemical Separation of Uranium and Precise Measurement of 234U/238U and 235U/238U Ratios in Soil Samples Using Multi Collector Inductively Coupled Plasma Mass Spectrometry

https://repo.qst.go.jp/records/79951
https://repo.qst.go.jp/records/79951
bdf051b4-224a-4c99-8779-3606a9220e49
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-05-12
タイトル
タイトル Chemical Separation of Uranium and Precise Measurement of 234U/238U and 235U/238U Ratios in Soil Samples Using Multi Collector Inductively Coupled Plasma Mass Spectrometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nimelan, Veerasamy

× Nimelan, Veerasamy

WEKO 944399

Nimelan, Veerasamy

Search repository
Takamasa, Asako

× Takamasa, Asako

WEKO 944400

Takamasa, Asako

Search repository
Murugan, Rajamanickam

× Murugan, Rajamanickam

WEKO 944401

Murugan, Rajamanickam

Search repository
Kasar, Sharayu

× Kasar, Sharayu

WEKO 944402

Kasar, Sharayu

Search repository
Aono, Tatsuo

× Aono, Tatsuo

WEKO 944403

Aono, Tatsuo

Search repository
Inoue, Kazumasa

× Inoue, Kazumasa

WEKO 944404

Inoue, Kazumasa

Search repository
Fukushi, Masahiro

× Fukushi, Masahiro

WEKO 944405

Fukushi, Masahiro

Search repository
Kumar Sahoo, Sarata

× Kumar Sahoo, Sarata

WEKO 944406

Kumar Sahoo, Sarata

Search repository
Nimelan, Veerasamy

× Nimelan, Veerasamy

WEKO 944407

en Nimelan, Veerasamy

Search repository
Asako, Takamasa

× Asako, Takamasa

WEKO 944408

en Asako, Takamasa

Search repository
Murugan, Rajamanickam

× Murugan, Rajamanickam

WEKO 944409

en Murugan, Rajamanickam

Search repository
Kasar, Sharayu

× Kasar, Sharayu

WEKO 944410

en Kasar, Sharayu

Search repository
Tatsuo, Aono

× Tatsuo, Aono

WEKO 944411

en Tatsuo, Aono

Search repository
Sahoo, Sarata

× Sahoo, Sarata

WEKO 944412

en Sahoo, Sarata

Search repository
抄録
内容記述タイプ Abstract
内容記述 A new chemical separation has been developed to isolate uranium (U) using two UTEVA columns to minimize iron and thorium interferences from high background area soil samples containing minerals like monazites and ilmenite. The separation method was successfully verified in some certified reference materials (CRMs), for example, JSd-2, JLk-1, JB-1 and JB-3. The same method was applied for purification of U in Fukushima soil samples affected by the Fukushima dai-ichi
nuclear power station (FDNPS) accident. Precise and accurate measurement of 234U/238U and 235U/238U isotope ratios in chemically separated U were carried out using a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS). In this mass spectrometric method, an array of two Faraday cups (10e11 Ω, 10e12 Ω resistor) and a Daly detector were simultaneously employed. The precision of U isotope ratios in an in-house standard was evaluated by replicate
measurement. Relative standard deviation (RSD) of 234U/238U and 235U/238U were found to be 0.094% (2σ) and 0.590% (2σ), respectively. This method has been validated using a standard reference material SRM 4350B, sediment sample. The replicate measurements of 234U/238U in SRM shows 0.7% (RSD). This developed method is suitable for separation of U and its isotope ratio measurement in environmental samples.
書誌情報 Molecules

巻 25, 号 9, p. 1-18, 発行日 2020-05
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 1420-3049
DOI
識別子タイプ DOI
関連識別子 10.3390/molecules25092138
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/1420-3049/25/9/2138
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:41:06.627589
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3