Preliminary survey of 3D image-guided brachytherapy for cervical cancer at representative hospitals in Asian countries.
https://repo.qst.go.jp/records/79943
https://repo.qst.go.jp/records/7994392f243cc-a496-495d-ba76-2cb0ef077941
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-05-11 | |||||
タイトル | ||||||
タイトル | Preliminary survey of 3D image-guided brachytherapy for cervical cancer at representative hospitals in Asian countries. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Okonogi, Noriyuki
× Okonogi, Noriyuki× Wakatsuki, Masaru× Mizuno, Hideyuki× Fukuda, Shigekazu× Cao, Jianping× Kodrat, Henry× Nee Lau, Fen× Joy Calaguas, Miriam× H de Los Reyes, Rey× Chansilpa, Yaowalak× F M Kamal Uddin, A× Adylkhanov, Tasbolat× Chul-Koo, Cho× Tsegmed, Uranchimeg× Cong Hoang, Nguyen× Ohno, Tatsuya× Nakano, Takashi× Kato, Shingo× Okonogi, Noriyuki× Wakatsuki, Masaru× Mizuno, Hideyuki× Fukuda, Shigekazu× Tsegmed, Uranchimeg× Ohno, Tatsuya× Nakano, Takashi× Kato, Shingo |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 3D image-guided brachytherapy (3D-IGBT) has become a standard therapy for cervical cancer. However, the use of 3D-IGBT is limited in East and Southeast Asia. This study aimed to clarify the current usage patterns of 3D-IGBT for cervical cancer in East and Southeast Asia. A questionnaire-based survey was performed in 11 countries within the framework of the Forum for Nuclear Cooperation in Asia. The questionnaire collected the treatment information of patients with cervical cancer who underwent 3D-IGBT. The cumulative external beam radiotherapy and 3D-IGBT doses were summarized and normalized to a biological equivalent dose of 2 Gy per fraction (EQD2) using a linear-quadratic model. Of the 11 institutions representing the participating countries, six (55%) responded to the questionnaire. Overall, data of 36 patients were collected from the six institutions. Twenty-one patients underwent whole-pelvic irradiation and 15 underwent whole-pelvic irradiation with central shielding. Patients received a median of four treatment sessions of 3D-IGBT (range, 2-6). All 3D-IGBT sessions were computed tomography (CT)-based and not magnetic resonance image-based. The median doses to the high-risk clinical target volume D90, bladder D2cc, rectum D2cc and sigmoid colon D2cc were 80.9 Gy EQD2 (range, 58.9-105.9), 77.7 Gy EQD2 (range, 56.9-99.1), 68.0 Gy EQD2 (range, 48.6-90.7) and 62.0 Gy EQD2 (range, 39.6-83.7), respectively. This study elucidated the current patterns of 3D-IGBT for the treatment of cervical cancer in East and Southeast Asia. The results indicate the feasibility of observational studies of CT-based 3D-IGBT for cervical cancer in these countries. | |||||
書誌情報 |
Journal of radiation research 巻 61, 号 4, p. 608-615, 発行日 2020-05 |
|||||
出版者 | ||||||
出版者 | Oxford University Press | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0449-3060 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 32367130 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/jrr/rraa025 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://academic.oup.com/jrr/article/61/4/608/5829024 |