{"_buckets": {"deposit": "e5427c55-9d6f-4c99-bede-b01186552634"}, "_deposit": {"created_by": 1, "id": "79775", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "79775"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00079775", "sets": ["1"]}, "author_link": ["882726", "882721", "882717", "882724", "882719", "882728", "882729", "882720", "882715", "882716", "882718", "882722", "882723", "882725", "882727", "882730"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-08", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "111632", "bibliographicVolumeNumber": "157", "bibliographic_titles": [{"bibliographic_title": "Fusion Engineering and Design"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In the conceptual design activity of advanced fusion neutron source A-FNS, a variety of test modules for fusion DEMO reactor are planned. In these modules, progresses of design activities on Blanket Nuclear Property Test Module (BNPTM) and Diagnostic and Control Device Test Module (DCDTM) were reported. The BNPTM is a module in order to evaluate accuracies of nuclear analyses of the DEMO blanket such as tritium production rate. The influences of the cooling water and test cell wall were evaluated in order to decide its design. The DCDTM is one to achieve irradiation data of functional materials on diagnostic and control devices such as mirror and window. It was clarified from its nuclear analysis that the neutron fluence obtained in the DCDTM was enough to investigate the accumulated irradiation effects on the materials. In addition to the irradiation tests on the fusion reactor materials, various neutron applications are planned at A-FNS. One of the applications is medical isotope production. We clarified that enough amount of the medical isotope molybdenum-99 could be produced in comparison with the demand in Japan by using Radio-Isotope Production Module (RIPM). The RIPM affects little influence on the fusion reactor material irradiation tests. ", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.fusengdes.2020.111632", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.sciencedirect.com/science/article/pii/S0920379620301800", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0920-3796", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "太田, 雅之"}], "nameIdentifiers": [{"nameIdentifier": "882715", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 聡"}], "nameIdentifiers": [{"nameIdentifier": "882716", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村, 誠"}], "nameIdentifiers": [{"nameIdentifier": "882717", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "権, セロム"}], "nameIdentifiers": [{"nameIdentifier": "882718", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "朴, 昶虎"}], "nameIdentifiers": [{"nameIdentifier": "882719", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "落合, 謙太郎"}], "nameIdentifiers": [{"nameIdentifier": "882720", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "染谷, 洋二"}], "nameIdentifiers": [{"nameIdentifier": "882721", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "春日井, 敦"}], "nameIdentifiers": [{"nameIdentifier": "882722", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ota, Masayuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882723", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, Satoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882724", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamura, Makoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882725", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Gon, Seromu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882726", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Park, ChangHo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882727", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ochiai, Kentaro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882728", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Someya, Yoji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882729", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kasugai, Atsushi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "882730", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Conceptual Design of Test Modules for DEMO Blanket, Diagnostic Device, and RI Production for A-FNS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Conceptual Design of Test Modules for DEMO Blanket, Diagnostic Device, and RI Production for A-FNS"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/79775", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-04-01"}, "publish_date": "2020-04-01", "publish_status": "0", "recid": "79775", "relation": {}, "relation_version_is_last": true, "title": ["Conceptual Design of Test Modules for DEMO Blanket, Diagnostic Device, and RI Production for A-FNS"], "weko_shared_id": -1}
Conceptual Design of Test Modules for DEMO Blanket, Diagnostic Device, and RI Production for A-FNS
https://repo.qst.go.jp/records/79775
https://repo.qst.go.jp/records/7977563f5c33c-aa71-4b90-a316-1659b0c5f8e8
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-04-01 | |||||
タイトル | ||||||
タイトル | Conceptual Design of Test Modules for DEMO Blanket, Diagnostic Device, and RI Production for A-FNS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
太田, 雅之
× 太田, 雅之× 佐藤, 聡× 中村, 誠× 権, セロム× 朴, 昶虎× 落合, 謙太郎× 染谷, 洋二× 春日井, 敦× Ota, Masayuki× Sato, Satoshi× Nakamura, Makoto× Gon, Seromu× Park, ChangHo× Ochiai, Kentaro× Someya, Yoji× Kasugai, Atsushi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In the conceptual design activity of advanced fusion neutron source A-FNS, a variety of test modules for fusion DEMO reactor are planned. In these modules, progresses of design activities on Blanket Nuclear Property Test Module (BNPTM) and Diagnostic and Control Device Test Module (DCDTM) were reported. The BNPTM is a module in order to evaluate accuracies of nuclear analyses of the DEMO blanket such as tritium production rate. The influences of the cooling water and test cell wall were evaluated in order to decide its design. The DCDTM is one to achieve irradiation data of functional materials on diagnostic and control devices such as mirror and window. It was clarified from its nuclear analysis that the neutron fluence obtained in the DCDTM was enough to investigate the accumulated irradiation effects on the materials. In addition to the irradiation tests on the fusion reactor materials, various neutron applications are planned at A-FNS. One of the applications is medical isotope production. We clarified that enough amount of the medical isotope molybdenum-99 could be produced in comparison with the demand in Japan by using Radio-Isotope Production Module (RIPM). The RIPM affects little influence on the fusion reactor material irradiation tests. | |||||
書誌情報 |
Fusion Engineering and Design 巻 157, p. 111632, 発行日 2020-08 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0920-3796 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.fusengdes.2020.111632 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0920379620301800 |