ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Secondary electron emission measurement from Cr and Cu bombarded by an Ne10+ beam at 6 MeV/n

https://repo.qst.go.jp/records/79639
https://repo.qst.go.jp/records/79639
e8ce9a7d-5efb-4e02-a320-217010ff57ec
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-03-25
タイトル
タイトル Secondary electron emission measurement from Cr and Cu bombarded by an Ne10+ beam at 6 MeV/n
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Higashi, Akio

× Higashi, Akio

WEKO 858906

Higashi, Akio

Search repository
Hashimoto, Yoshinori

× Hashimoto, Yoshinori

WEKO 858907

Hashimoto, Yoshinori

Search repository
Ohsawa, Daisuke

× Ohsawa, Daisuke

WEKO 858908

Ohsawa, Daisuke

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 858909

Shirai, Toshiyuki

Search repository
Noda, Koji

× Noda, Koji

WEKO 858910

Noda, Koji

Search repository
Higashi, Akio

× Higashi, Akio

WEKO 858911

en Higashi, Akio

Search repository
Hashimoto, Yoshinori

× Hashimoto, Yoshinori

WEKO 858912

en Hashimoto, Yoshinori

Search repository
Ohsawa, Daisuke

× Ohsawa, Daisuke

WEKO 858913

en Ohsawa, Daisuke

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 858914

en Shirai, Toshiyuki

Search repository
Noda, Koji

× Noda, Koji

WEKO 858915

en Noda, Koji

Search repository
抄録
内容記述タイプ Abstract
内容記述 Backward secondary-electron-emission yield (δ) from plates of 0.1 mm-thick Cu and 1mm Cr and Al have been measured by irradiation of a fully stripped Ne10+ beam at 6 MeV/n stopped within each plate. A difference between δs from Cr and Cu larger than the ambiguity of this measurement (±3%) has been observed, with the discrepancy of the predicted small difference by kinetic emission based on stopping power and work function of each metal. The measured δ from Cr is larger than that from Cu, and also than previous measurements of other transition metals of the 3d series, not only for the process of potential emission but also for kinetic. The conduction-electron density of states around the Fermi level calculated for the metals shows that the number of electrons just below the Fermi level and excited over it to an empty level by many kinds of reaction with the beam irradiation has to be considered. The number involved in this emission from Cr thus seems to be much larger than from Cu, which explains the relation of magnitudes for δ. The measured δ from Al is larger than previous results, but is still consistent due to the existence of Al2O3 on the Al.
書誌情報 Progress of Theoretical and Experimental Physics (PTEP)

巻 2020, 号 3, p. 033101, 発行日 2020-03
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 2050-3911
DOI
識別子タイプ DOI
関連識別子 10.1093/ptep/ptaa006
関連サイト
識別子タイプ URI
関連識別子 https://academic.oup.com/ptep/article/2020/3/033I01/5809551
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:12:44.288364
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3