ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Stability diagnosis of orthopedic implants based on resonance frequency analysis with fiber transmission of nanosecond laser pulse and acceleration sensor

https://repo.qst.go.jp/records/79559
https://repo.qst.go.jp/records/79559
4b07471a-4202-492f-bf38-adac3fad5b82
Item type 会議発表論文 / Conference Paper(1)
公開日 2020-03-13
タイトル
タイトル Stability diagnosis of orthopedic implants based on resonance frequency analysis with fiber transmission of nanosecond laser pulse and acceleration sensor
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mikami, Katsuhiro

× Mikami, Katsuhiro

WEKO 909738

Mikami, Katsuhiro

Search repository
Nakashima, Daisuke

× Nakashima, Daisuke

WEKO 909739

Nakashima, Daisuke

Search repository
Kikuchi, Shunsuke

× Kikuchi, Shunsuke

WEKO 909740

Kikuchi, Shunsuke

Search repository
Kitamura, Toshiyuki

× Kitamura, Toshiyuki

WEKO 909741

Kitamura, Toshiyuki

Search repository
Hasegawa, Noboru

× Hasegawa, Noboru

WEKO 909742

Hasegawa, Noboru

Search repository
Nagura, Takeo

× Nagura, Takeo

WEKO 909743

Nagura, Takeo

Search repository
Nishikino, Masaharu

× Nishikino, Masaharu

WEKO 909744

Nishikino, Masaharu

Search repository
Kitamura, Toshiyuki

× Kitamura, Toshiyuki

WEKO 909745

en Kitamura, Toshiyuki

Search repository
Hasegawa, Noboru

× Hasegawa, Noboru

WEKO 909746

en Hasegawa, Noboru

Search repository
Nishikino, Masaharu

× Nishikino, Masaharu

WEKO 909747

en Nishikino, Masaharu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Stability of orthopedic implant such as pedicle screw and acetabular cup is essential to prevent bone union failure. The subsequent complication is cause further surgery because of its aberration and looseness. A quantitative diagnosis approach which can be adaptable in surgery was developed resonance frequency analysis scheme based on laser induced vibration. As a principle of the diagnosis, a laser pulse irradiated onto the orthopedic implants to induce vibration, then the induced vibration was measured by acceleration sensor or laser Doppler vibrometer. The measured signal was analysed by fast Fourier transform method. In the case of the evaluation for acetabular cup which was set by press-fit, one of the peak frequencies of the induced vibration were increased with increasing an index of the stability defined by pull-down force as mechanical evaluation. The diagnosis scheme was considered for adaptation to surgery situation including usage for another implants and flexible handling. Optical multimode fiber and pedicle screw were used for validation. The stability diagnosis system was proposed as quantitative evaluation scheme adaptable in the surgery situation.
書誌情報 Proc. of SPIE

巻 11233, p. 112330O, 発行日 2020-03
DOI
識別子タイプ DOI
関連識別子 10.1117/12.2544793
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:54:13.177745
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3