Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup

https://repo.qst.go.jp/records/79550
https://repo.qst.go.jp/records/79550
593e5de5-eeeb-432e-ac0e-e759aed16644
Item type 会議発表用資料 / Presentation(1)
公開日 2020-03-18
タイトル
タイトル Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizuno, Kosuke

× Mizuno, Kosuke

WEKO 856363

Mizuno, Kosuke

Search repository
Ishiwata, Hitoshi

× Ishiwata, Hitoshi

WEKO 856364

Ishiwata, Hitoshi

Search repository
Masuyama, Yuta

× Masuyama, Yuta

WEKO 856365

Masuyama, Yuta

Search repository
Iwasaki, Takayuki

× Iwasaki, Takayuki

WEKO 856366

Iwasaki, Takayuki

Search repository
Hatano, Mutsuko

× Hatano, Mutsuko

WEKO 856367

Hatano, Mutsuko

Search repository
Masuyama, Yuta

× Masuyama, Yuta

WEKO 856368

en Masuyama, Yuta

Search repository
Hatano, Mutsuko

× Hatano, Mutsuko

WEKO 856369

en Hatano, Mutsuko

Search repository
抄録
内容記述タイプ Abstract
内容記述 The nitrogen-vacancy center in diamond is an exquisite solid-state sensor based upon quantum nature. Numerous studies have shown that dynamical decoupling, such as an XY8 sequence, provides us a high sensitivity for an oscillating magnetic field parametrized by amplitude and phase. However, there are some drawbacks. (1) A measurement using XY8 requires a careful adjustment of timings between XY8 sequences and the target signal. (2) The XY8 has an intricate dependence on both parameters, so it is not applicable in a situation that both parameters simultaneously change. (3) It is impossible to measure both parameters simultaneous, and they have to be measured severally. In this study, we present that Qdyne1-3, a quantum-classical hybrid protocol, solves them, consisted of sequential and stroboscopic measurements. The Qdyne does not require a timing adjustment before itself, has an intuitive dependency on both parameters, and let us a simultaneous measurement of both amplitude and phase. Moreover, we implemented it on a widefield of view. The large observation area of widefield modality and the high spatial resolution of NV center pave the way for a tiny-scale inspection by Eddy-current, which established sensors cannot detect.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 2nd International Forum on Quantum Metrology and Sensing への出席
発表年月日
日付 2019-12-17
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:13:43.641645
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3