ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Sensitivity improvement of YAP(Ce) cameras for imaging of secondary electron bremsstrahlung X-rays emitted during carbon-ion irradiation: Problem and solution

https://repo.qst.go.jp/records/79400
https://repo.qst.go.jp/records/79400
f3f59537-d2e5-4c1b-8fc4-b383c34226ba
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-02-26
タイトル
タイトル Sensitivity improvement of YAP(Ce) cameras for imaging of secondary electron bremsstrahlung X-rays emitted during carbon-ion irradiation: Problem and solution
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Seiichi, Yamamoto (Nagoya Univ.)

× Seiichi, Yamamoto (Nagoya Univ.)

WEKO 870248

Seiichi, Yamamoto (Nagoya Univ.)

Search repository
Yamaguchi, Mitsutaka

× Yamaguchi, Mitsutaka

WEKO 870249

Yamaguchi, Mitsutaka

Search repository
Takashi, Akagi (Hyogo Ion Beam Medical Center)

× Takashi, Akagi (Hyogo Ion Beam Medical Center)

WEKO 870250

Takashi, Akagi (Hyogo Ion Beam Medical Center)

Search repository
Maki, Kitano (Nagoya Univ.)

× Maki, Kitano (Nagoya Univ.)

WEKO 870251

Maki, Kitano (Nagoya Univ.)

Search repository
Kawachi, Naoki

× Kawachi, Naoki

WEKO 870252

Kawachi, Naoki

Search repository
Yamaguchi, Mitsutaka

× Yamaguchi, Mitsutaka

WEKO 870253

en Yamaguchi, Mitsutaka

Search repository
Kawachi, Naoki

× Kawachi, Naoki

WEKO 870254

en Kawachi, Naoki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Low-energy X-ray imaging of secondary electron bremsstrahlung X-rays emitted during carbon-ion irradiation is a promising method for range estimation and could be used for imaging with almost clinical dose levels of carbon ion. However, the number of counts in images with clinical dose levels is relatively small, making it difficult to obtain precise range estimations. Since improving the sensitivity of the X-ray camera may solve this issue, we developed two new types of X-ray cameras. One uses a 1-mm thick, 40 mm × 40-mm cerium-doped yttrium aluminum perovskite (YAP(Ce)) scintillator plate combined with a 2-inch square flat panel photomultiplier tube (FP-PMT) contained in a 2-cm thick tungsten shield with a pinhole collimator positioned 50 mm from the scintillator; the other uses a 0.5-mm thick, 20 mm × 20-mm YAP(Ce) scintillator plate combined with a 1-inch square position sensitive photomultiplier tube (PS-PMT) contained in the same tungsten shield with a pinhole collimator, but with the scintillator positioned closer (30 mm) to the pinhole collimator to obtain a similar field-of-view (FOV). For both cameras, we used a wider angle (~55 degrees) pinhole collimator to measure the phantom closer to improve sensitivity. Although the 40 mm × 40-mm YAP(Ce) camera had high system spatial resolution, the background count fractions were high and produced a high count area at the center of the images due to the pulse pileup of the signals. With the 20 mm × 20-mm YAP(Ce) camera, we obtained X-ray images with low background counts without a high count area at the image center. By smoothing the measured images, we were able to estimate the ranges even for clinical dose levels. We therefore confirmed that one of our newly developed YAP(Ce) cameras had high sensitivity and is promising for the imaging of secondary electron bremsstrahlung X-rays during irradiation of carbon ions in clinical conditions.
書誌情報 Phys. Med. Biol.

巻 65, 号 10, p. 105008-1-105008-15, 発行日 2020-03
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ab7a6e
関連サイト
識別子タイプ URI
関連識別子 https://iopscience.iop.org/article/10.1088/1361-6560/ab7a6e
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:06:59.293543
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3