ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Effects of Resonance Phenomenon Caused by Power Supply on JT-60SA CS

https://repo.qst.go.jp/records/79288
https://repo.qst.go.jp/records/79288
7d604b02-369e-406e-b3f6-bb192a95aa3f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-03-10
タイトル
タイトル Effects of Resonance Phenomenon Caused by Power Supply on JT-60SA CS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Meguro, Hirotaka

× Meguro, Hirotaka

WEKO 1005170

Meguro, Hirotaka

Search repository
Nakamura, Kazuya

× Nakamura, Kazuya

WEKO 1005171

Nakamura, Kazuya

Search repository
Sonoda, Shogo

× Sonoda, Shogo

WEKO 1005172

Sonoda, Shogo

Search repository
Nasu, Keisuke

× Nasu, Keisuke

WEKO 1005173

Nasu, Keisuke

Search repository
Murakami, Haruyuki

× Murakami, Haruyuki

WEKO 1005174

Murakami, Haruyuki

Search repository
Kizu, Kaname

× Kizu, Kaname

WEKO 1005175

Kizu, Kaname

Search repository
Haruyuki, Murakami

× Haruyuki, Murakami

WEKO 1005176

en Haruyuki, Murakami

Search repository
Kaname, Kizu

× Kaname, Kizu

WEKO 1005177

en Kaname, Kizu

Search repository
抄録
内容記述タイプ Abstract
内容記述 The maximum voltage between the CS module terminals is designed to be 10 kV, the voltage between the layers under ideal conditions is then about 0.38 kV because the CS module has 52 layers. But, in operating condition, there is a possibility that the voltage between the layers is higher than 0.38 kV due to the
voltage fluctuations of the power supply and the inhomogeneous voltage distribution in the CS module induced by the resonance phenomenon. The JT-60SA CS consists of four electrically independent stacked CS modules. It might even produce voltages high enough to damage the insulation between the CS conductors. In the present study, which is based on the results of previous studies, we created a circuit simulation model for the JT-60SA CS (four CS modules), including the structures (ground resistances, CS structure, TFC cases, and EFC covers), and used it to estimate the voltage distribution produced by the resonance phenomenon. From these results, we conclude that the resonance phenomenon caused by power supply frequency components does not impact the insulation between the CS conductors, and hence the JT-60SA CS is electrically stable under normal operating conditions.
書誌情報 IEEE Transactions on Applied Superconductivity

巻 30, 号 4, p. 4201705, 発行日 2020-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 1051-8223
DOI
識別子タイプ DOI
関連識別子 10.1109/TASC.2020.2970392
関連サイト
識別子タイプ URI
関連識別子 https://ieeexplore.ieee.org/document/8976100
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:27:04.428516
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3