ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Multidisciplinary applications by use of ultra-compact neutron source based on inertial electrostatic confinement fusion devise at Kyoto University

https://repo.qst.go.jp/records/79156
https://repo.qst.go.jp/records/79156
0abd1b92-c638-423a-8545-e57126524391
Item type 会議発表用資料 / Presentation(1)
公開日 2020-03-03
タイトル
タイトル Multidisciplinary applications by use of ultra-compact neutron source based on inertial electrostatic confinement fusion devise at Kyoto University
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Bakr, Mahmoud

× Bakr, Mahmoud

WEKO 867803

Bakr, Mahmoud

Search repository
Masuda, Kai

× Masuda, Kai

WEKO 867804

Masuda, Kai

Search repository
Mukai, K.

× Mukai, K.

WEKO 867805

Mukai, K.

Search repository
Konishi, S.

× Konishi, S.

WEKO 867806

Konishi, S.

Search repository
Masuda, Kai

× Masuda, Kai

WEKO 867807

en Masuda, Kai

Search repository
抄録
内容記述タイプ Abstract
内容記述 Neutrons were discovered for the first time by Chadwick in 1932 [1]. Since that time, neutrons have been intensively used in wide-scale applications, such as medicine, biology, material science, radiography, explosive detection, nuclear security, power generations, …etc. The type of applications depends strongly on the neutron source characteristics, such as source size, safety, handling method, and the neutron flux. We are developing the first of its kind portable and an ultra-compact neutron source based on the inertial electrostatic confinement fusion (IECF) device for multidisciplinary applications in Kyoto University [2]. In the IECF device, the neutrons are generated from the fusion combustion of deuterium–deuterium (D-D), or deuterium-tritium (D-T) fuels. The neutron production rate from the portable IECF system operated using DD fule, so far, is 1x108 neutron/sec by applying only 5.5 kW power to the system. The IECF device characterizations, the principle of operation and the on-going applications in nuclear security, boron neutron capture therapy (BNCT), and radiography applications will be presented and discussed in the conference.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 12th International Conference on Nuclear Sciences and Application
発表年月日
日付 2020-02-16
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:07:50.203732
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3