Measurements of thermal-neutron capture cross-section of Cesium-135 by applying mass spectrometry

https://repo.qst.go.jp/records/79020
https://repo.qst.go.jp/records/79020
e1976ebb-836b-4427-858e-9ee644f5fdc6
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-02-20
タイトル
タイトル Measurements of thermal-neutron capture cross-section of Cesium-135 by applying mass spectrometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakamura, Shoji

× Nakamura, Shoji

WEKO 1005013

Nakamura, Shoji

Search repository
Shibahara, Yuji

× Shibahara, Yuji

WEKO 1005014

Shibahara, Yuji

Search repository
Kimura, Atsushi

× Kimura, Atsushi

WEKO 1005015

Kimura, Atsushi

Search repository
Iwamoto, Osamu

× Iwamoto, Osamu

WEKO 1005016

Iwamoto, Osamu

Search repository
Uehara, Akihiro

× Uehara, Akihiro

WEKO 1005017

Uehara, Akihiro

Search repository
Fujii, Toshiyuki

× Fujii, Toshiyuki

WEKO 1005018

Fujii, Toshiyuki

Search repository
Akihiro, Uehara

× Akihiro, Uehara

WEKO 1005019

en Akihiro, Uehara

Search repository
抄録
内容記述タイプ Abstract
内容記述 The thermal-neutron capture cross-section (σ0) and resonance integral (I0) were measured for the 135Cs(n,γ)136Cs reaction by an activation method and mass spectrometry. Because of difficulty in the preparation of pure 135Cs samples, we used 135Cs contained as an impurity in a normally available 137Cs standard solution. An isotope ratio of 135Cs and 137Cs in a standard 137Cs solution was measured by mass spectrometry to quantify 135Cs. Cesium-135 impurity along with the 137Cs standard solution was irradiated at the hydraulic conveyer of the research reactor in the Institute for Integral Radiation and Nuclear Science, Kyoto University. Wires of Co/Al and Au/Al alloys were used as neutron monitors to measure thermal-neutron fluxes and epi-thermal Westcott’s indices at an irradiation position. A gadolinium filter was used to measure the σ0, and a value of 0.133 eV was taken as the cut-off energy. Gamma-ray spectroscopy was used to measure induced activities of 137Cs, 136Cs and monitor wires. On the basis of Westcott’s convention, the σ0 and I0 values were derived as 8.57 ± 0.25 barn, and 45.3 ± 3.2 barn, respectively. The value of σ0 obtained in the present study agreed within the limits of uncertainties with the past-reported value of 8.3 ± 0.3 barn.
書誌情報 Journal of Nuclear Science and Technology

巻 57, 号 4, p. 388-400, 発行日 2019-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0022-3131
DOI
識別子タイプ DOI
関連識別子 10.1080/00223131.2019.1691077
関連サイト
識別子タイプ URI
関連識別子 https://www.tandfonline.com/doi/full/10.1080/00223131.2019.1691077
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:27:11.232073
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3