ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Variable Strength in Thoron Interference for a Diffusion-Type Radon Monitor Depending on Ventilation of the Outer Air

https://repo.qst.go.jp/records/78940
https://repo.qst.go.jp/records/78940
71ae6741-63e5-4eea-b329-2e7c0d72c662
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-02-10
タイトル
タイトル Variable Strength in Thoron Interference for a Diffusion-Type Radon Monitor Depending on Ventilation of the Outer Air
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Omori, Yasutaka

× Omori, Yasutaka

WEKO 1004806

Omori, Yasutaka

Search repository
Shimo, Michikuni

× Shimo, Michikuni

WEKO 1004807

Shimo, Michikuni

Search repository
Janik, Miroslaw

× Janik, Miroslaw

WEKO 1004808

Janik, Miroslaw

Search repository
Ishikawa, Tetsuo

× Ishikawa, Tetsuo

WEKO 1004809

Ishikawa, Tetsuo

Search repository
Hidenori Yonehara

× Hidenori Yonehara

WEKO 1004810

Hidenori Yonehara

Search repository
Yasutaka, Omori

× Yasutaka, Omori

WEKO 1004811

en Yasutaka, Omori

Search repository
Janik, Miroslaw

× Janik, Miroslaw

WEKO 1004812

en Janik, Miroslaw

Search repository
抄録
内容記述タイプ Abstract
内容記述 Thoron interference in radon measurements using passive diffusion radon
detectors/monitors is a crucial problem when it comes to assessing the internal exposure to radon precisely. The present study reported, as one of the potential factors, the effects of air flow conditions on changes in thoron interference. Rates of thoron infiltration (as thoron interference) into the diffusion chamber of the monitor were evaluated. The temporal variation was obtained based on
measurements of the underfloor space of a Japanese wooden dwelling using a diffusion-type radon monitor, a reference radon monitor which was not affected by thoron interference, and a thoron monitor. The thoron infiltration rate for the diffusion-type monitor varied from 0% to 20%. In particular, it appeared to increase when ventilation of the underfloor space air was forced. The variable thoron infiltration rate, with respect to ventilation strength, implied that not only a
diffusive process, but also an advective process, played a major role in air exchange between the diffusion chamber of the monitor and the outer air. When an exposure room is characterized by the frequent variation in air ventilation, a variable thoron response is considered to occur in radon–thoron discriminative detectors, in which only diffusive entry is employed as a mechanism for the
discrimination of radon and thoron.
書誌情報 International Journal of Environmental Research and Public Health

巻 17, 号 3, 発行日 2020-02
出版者
出版者 MDPI, St. Alban-Anlage 66, 4052 Basel, Switzerland
ISSN
収録物識別子タイプ ISSN
収録物識別子 1660-4601
DOI
識別子タイプ DOI
関連識別子 10.3390/ijerph17030974
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/1660-4601/17/3/974
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:27:21.920368
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3