ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Regression model-based real-time markerless tumor tracking with fluoroscopic images for hepatocellular carcinoma

https://repo.qst.go.jp/records/78935
https://repo.qst.go.jp/records/78935
d5979611-8ee8-492b-91d6-06ca68bd88aa
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-02-10
タイトル
タイトル Regression model-based real-time markerless tumor tracking with fluoroscopic images for hepatocellular carcinoma
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirai, Ryusuke

× Hirai, Ryusuke

WEKO 1004800

Hirai, Ryusuke

Search repository
Sakata, Yukinobu

× Sakata, Yukinobu

WEKO 1004801

Sakata, Yukinobu

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 1004802

Mori, Shinichiro

Search repository
Ryusuke, Hirai

× Ryusuke, Hirai

WEKO 1004803

en Ryusuke, Hirai

Search repository
Yukinobu, Sakata

× Yukinobu, Sakata

WEKO 1004804

en Yukinobu, Sakata

Search repository
Shinichiro, Mori

× Shinichiro, Mori

WEKO 1004805

en Shinichiro, Mori

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: We have developed a new method to track tumor position using fluoroscopic images, and evaluated it using hepatocellular carcinoma case data.
Methods: Our method consists of a training stage and a tracking stage. In the training stage, the model data for the positional relationship between the diaphragm and the tumor are calculated using four-dimensional com- puted tomography (4DCT) data. The diaphragm is detected along a straight line, which was chosen to avoid 4DCT artifact. In the tracking stage, the tumor position on the fluoroscopic images is calculated by applying the model to the diaphragm. Using data from seven liver cases, we evaluated four metrics: diaphragm edge detection error, modeling error, patient setup error, and tumor tracking error. We measured tumor tracking error for the 15 fluoroscopic sequences from the cases and recorded the computation time.
Results: The mean positional error in diaphragm tracking was 0.57 ± 0.62 mm. The mean positional error in tumor tracking in three-dimensional (3D) space was 0.63 ± 0.30 mm by modeling error, and 0.81–2.37 mm with 1–2 mm setup error. The mean positional error in tumor tracking in the fluoroscopy sequences was 1.30 ± 0.54 mm and the mean computation time was 69.0 ± 4.6 ms and 23.2 ± 1.3 ms per frame for the training and tracking stages, respectively.
Conclusions: Our markerless tracking method successfully estimated tumor positions. We believe our results will be useful in increasing treatment accuracy for liver cases.
書誌情報 Physica Medica

巻 70, p. 196-205, 発行日 2020-02
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 1120-1797
DOI
識別子タイプ DOI
関連識別子 10.1016/j.ejmp.2020.02.001
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/abs/pii/S1120179720300326
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:27:21.225370
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3