WEKO3
アイテム
Synthesis of surface ion‑imprinted polymer for specific detection of thorium under acidic conditions
https://repo.qst.go.jp/records/78463
https://repo.qst.go.jp/records/78463da838dbc-7b0d-44bb-82d2-80e4af70dba9
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2020-01-20 | |||||
| タイトル | ||||||
| タイトル | Synthesis of surface ion‑imprinted polymer for specific detection of thorium under acidic conditions | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Othman, N.A.F.
× Othman, N.A.F.× Selambakkannu, S.× Azian, H.× C.T.Ratnam× Yamanobe, T.× Hoshina, Hiroyuki× Seko, Noriaki× Hiroyuki, Hoshina× Noriaki, Seko |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | A fibrous surface ion-imprinted polymer (IIP) was synthesized for thorium removal through direct electron beam radiation using thorium as a template. Polypropylene coated by polyethylene non-woven fabrics (PE/PP) was used as a substrate. The PE/ PP non-woven fabrics were irradiated in the presence of the phosphoric monomer (2-HMPA) composed of 2-hydroxyethyl methacrylic phosphoric acid diester (50%) and monoester (50%) emulsified with the crosslinker. Hence, the formation of the three-dimensional IIP-Th crosslinked network and complexation between thorium (template) and 2-HMPA was investigated. The emulsion stability and particle size distribution of emulsion were determined using dynamic light scattering (DLS). Various factors influencing the synthesis of the thorium ion-imprinted (Th-IIP) nonwoven PE/PP such as the absorbed radiation dose, monomer concentration, and type of crosslinker were investigated. The IIP-Th was characterized by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy–energy-dispersive X-ray (SEM–EDX), and X-ray photoelectron spectroscopy (XPS) and applied as an adsorbent for the removal of thorium using the batch adsorption method. The IIP-Th achieved a maximum distribution coefficient of 3.293 g/L and selectivity ratio (Th(IV)/U(VI)) of 9.5 after 90 min of contact time under acidic conditions. The adsorption kinetics of IIP-Th followed the pseudo-second-order kinetic model for both Th(IV) adsorption and U(VI) adsorption. The synthesized fibrous surface ion-imprinted polymer is a promising candidate for the selective removal of thorium ions from aqueous solution. | |||||
| 書誌情報 |
Polymer Bulletin 巻 78, p. 165-183, 発行日 2020-01 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0170-0839 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1007/s00289-019-03094-2 | |||||
| 関連サイト | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | https://doi.org/10.1007/s00289-019-03094-2 | |||||