アイテム

  1. その他誌上発表

ISO 22127 (Dosimetry with radiophotoluminescent glass dosimeters for dosimetry audit in MV X-ray radiotherapy)

https://repo.qst.go.jp/records/78418
https://repo.qst.go.jp/records/78418
451c8562-3833-432b-8bf0-9c11aa36d768
Item type 一般雑誌記事 / Article(1)
公開日 2020-01-14
タイトル
タイトル ISO 22127 (Dosimetry with radiophotoluminescent glass dosimeters for dosimetry audit in MV X-ray radiotherapy)
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 824152

Mizuno, Hideyuki

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 824153

Fukumura, Akifumi

Search repository
Akahane, Keiichi

× Akahane, Keiichi

WEKO 824154

Akahane, Keiichi

Search repository
Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 824155

en Mizuno, Hideyuki

Search repository
Fukumura, Akifumi

× Fukumura, Akifumi

WEKO 824156

en Fukumura, Akifumi

Search repository
Akahane, Keiichi

× Akahane, Keiichi

WEKO 824157

en Akahane, Keiichi

Search repository
抄録
内容記述タイプ Abstract
内容記述 A radiophotoluminescent glass dosimeter (RPLD) is a cumulative radiation dosimeter usually made of silver-activated phosphate glass. The silver atoms act as radiophotoluminescence (RPL) centres excited by ionizing radiation. The number of RPL centres excited is proportional to the absorbed dose to the RPLD. Since the first RPLD was produced in 1949, improvements have been made to the reading precision and reliability[1]. The latest products, rod-like dosimeters of a few millimetres in size, measure the absorbed dose that can be evaluated with an uncertainty of about 1 % to 2 % (k = 1) in certain conditions[2] to [5]. The RPL centres do not disappear after readout. Therefore, repeated readouts for a single exposure is possible. The results are stable and good accuracy of the signal readouts is possible. In addition, since the RPL centres once formed are hardly affected by fading, it is suitable in long-term dose measurement with retention capacity. RPLDs can be reused by annealing at high temperature.
RPLDs have been widely used for personal dosimetry and environmental radiation measurements[6] to [7].They are also used for radiation dose assessment of patients and staff in the field of radiation medicine, including interventional radiology, external radiotherapy, and brachytherapy[8] to [21]. Due to their advantages of compactness, repeatable readout, good precision, and small fading, RPLDs have been recently used as a dosimeter for dosimetric external audits in external radiotherapy with high-energy X‑rays[22] to [27]. Thermoluminescent Dosimeter (TLD) and optically stimulated luminescent dosimeter (OSLD) have also been used for the audits. The three dosimeters, RPLD, TLD, and OSLD, are passive solid-state dosimeters and have some similar characteristics. However, there are variations in the handling, reading methodology, and dose evaluation, including tissue-equivalency.
This document focuses on the RPL dosimetry from the viewpoint of the dosimetry audit in MV X‑ray radiotherapy highlighting the procedures for handling, reading, and corrections to the response dependency of beam quality and dose.
書誌情報 ISO 22127 (Dosimetry with radiophotoluminescent glass dosimeters for dosimetry audit in MV X-ray radiotherapy)

発行日 2019-12
出版者
出版者 ISO
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:28:47.750767
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3